This paper presents a novel human joint motion recording method, The recorded data are sent to the receiver, which is placed in the close proximity or in the same room with the patient, via a wireless short-range communications system that guarantees 3 days of battery life. This method exploits commercially available bend sensors to convert mechanical human joint movements into electric signals which are then acquired, pre-processed, wireless transmitted and post-processed. We propose a novel way of sensor’s application, underlying advantages and drawbacks which could be drastically reduced by electronic circuitry anyway. The network configuration and the specific air interface are chosen to satisfy system requirements in terms of data rates, battery autonomy, and mobility
Saggio, G., DE SANCTIS, M., Cianca, E., Latessa, G., De Santis, F., Giannini, F. (2009). Long term measurement of human joint movements for health care and rehabilitation purposes. In 1st International Conference on Wireless Communication, Vehicular Technology, Information Theory and Aerospace & Electronic Systems Technology, 2009 Wireless VITAE 2009. 1st International Conference on (pp.674-678). Aalborg : IEEE [10.1109/WIRELESSVITAE.2009.5172528].
Long term measurement of human joint movements for health care and rehabilitation purposes
SAGGIO, GIOVANNI;DE SANCTIS, MAURO;CIANCA, ERNESTINA;GIANNINI, FRANCO
2009-05-20
Abstract
This paper presents a novel human joint motion recording method, The recorded data are sent to the receiver, which is placed in the close proximity or in the same room with the patient, via a wireless short-range communications system that guarantees 3 days of battery life. This method exploits commercially available bend sensors to convert mechanical human joint movements into electric signals which are then acquired, pre-processed, wireless transmitted and post-processed. We propose a novel way of sensor’s application, underlying advantages and drawbacks which could be drastically reduced by electronic circuitry anyway. The network configuration and the specific air interface are chosen to satisfy system requirements in terms of data rates, battery autonomy, and mobilityFile | Dimensione | Formato | |
---|---|---|---|
WV096137Long Term Measurement of Human Joint...PDF
accesso aperto
Descrizione: Long Term Measurement of Human Joint Movements for Health Care and Rehabilitation Purposes
Dimensione
1.16 MB
Formato
Adobe PDF
|
1.16 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.