The NA62 experiment at CERN SPS aiiiiB to measure the Branching Ratio of the very rare kaon decay K+ â Ï + ν Î½Ì collecting 0(100) events with a 10% background to make a stringent test of the Standard Model. One of the main backgrounds to the prop011ed measurement is represented by the K+â Ï + Ï 0 decay. To suppress this background a.n efficient photo veto system is foreseen. In the 1-10 mrad angular region the NA48 high performance liquid krypton electromagnetic calorimeter is used. The design, implementation and current status of the Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger are presented.

Fucci, A., Paoluzzi, G., Salamon, A., Salina, G., Santovetti, E., Scarfl, F., et al. (2012). The NA62 liquid krypton electromagnetic calorimeter level 0 trigger. In Astroparticle, Particle, Space Physics and Detectors for Physics Applications - Proceedings of the 13th ICATPP Conference (pp.525-529). Como [10.1142/9789814405072_0077].

The NA62 liquid krypton electromagnetic calorimeter level 0 trigger

SANTOVETTI, EMANUELE;BONAIUTO, VINCENZO;SARGENI, FAUSTO
2012-01-01

Abstract

The NA62 experiment at CERN SPS aiiiiB to measure the Branching Ratio of the very rare kaon decay K+ â Ï + ν Î½Ì collecting 0(100) events with a 10% background to make a stringent test of the Standard Model. One of the main backgrounds to the prop011ed measurement is represented by the K+â Ï + Ï 0 decay. To suppress this background a.n efficient photo veto system is foreseen. In the 1-10 mrad angular region the NA48 high performance liquid krypton electromagnetic calorimeter is used. The design, implementation and current status of the Liquid Krypton Electromagnetic Calorimeter Level 0 Trigger are presented.
13th International Conference on Advanced Technology and Particle Physics, ICATPP 2011
Rilevanza internazionale
contributo
2012
Settore FIS/04 - FISICA NUCLEARE E SUBNUCLEARE
English
Angular regions; Branching ratio; Current status; Electromagnetic calorimeter; Rare kaon decay; Stringent test; The standard model, High energy physics; Readout systems, Liquids
Intervento a convegno
Fucci, A., Paoluzzi, G., Salamon, A., Salina, G., Santovetti, E., Scarfl, F., et al. (2012). The NA62 liquid krypton electromagnetic calorimeter level 0 trigger. In Astroparticle, Particle, Space Physics and Detectors for Physics Applications - Proceedings of the 13th ICATPP Conference (pp.525-529). Como [10.1142/9789814405072_0077].
Fucci, A; Paoluzzi, G; Salamon, A; Salina, G; Santovetti, E; Scarfl, F; Bonaiuto, V; Sargeni, F
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/98160
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 1
social impact