International Standards impose to Distributed Energy Resources, connected to the grid by an inverter, to detect an islanding condition within a suitable time interval. In this paper a Phase Locked Loop (PLL), based on a third-order prediction-correction filter, is proposed to implement an islanding detector with reduced detection time. Such feature is obtained using the estimation of the grid angular frequency and acceleration provided by the PLL with a negligible time delay. The proposed approach is implemented on a DSP and validated through an experimental comparison among different detection methods, such as Rate of Change of Frequency (ROCOF) and Sleep Mode frequency Shift (SMS). A combined use of ROCOF and SMS is also illustrated and discussed. © 2013 IEEE.

Bifaretti, S. (2013). Anti-islanding detector based on a robust PLL. In 2013 IEEE Energy Conversion Congress and Exposition, ECCE 2013 (pp.2934-2940). Denver, CO : IEEE [10.1109/ECCE.2013.6647083].

Anti-islanding detector based on a robust PLL

BIFARETTI, STEFANO
2013-09-01

Abstract

International Standards impose to Distributed Energy Resources, connected to the grid by an inverter, to detect an islanding condition within a suitable time interval. In this paper a Phase Locked Loop (PLL), based on a third-order prediction-correction filter, is proposed to implement an islanding detector with reduced detection time. Such feature is obtained using the estimation of the grid angular frequency and acceleration provided by the PLL with a negligible time delay. The proposed approach is implemented on a DSP and validated through an experimental comparison among different detection methods, such as Rate of Change of Frequency (ROCOF) and Sleep Mode frequency Shift (SMS). A combined use of ROCOF and SMS is also illustrated and discussed. © 2013 IEEE.
2013 IEEE Energy Conversion Congress and Exposition, ECCE 2013
Denver, CO, USA
2013
IEEE
Rilevanza internazionale
set-2013
Settore ING-IND/32 - CONVERTITORI, MACCHINE E AZIONAMENTI ELETTRICI
English
Angular frequencies; Distributed Energy Resources; Experimental comparison; International standards; Islanding conditions; Phase Locked Loop (PLL); Prediction-correction; Rate of change of frequencies, Energy conversion; Frequency estimation, Electric power distribution
Intervento a convegno
Bifaretti, S. (2013). Anti-islanding detector based on a robust PLL. In 2013 IEEE Energy Conversion Congress and Exposition, ECCE 2013 (pp.2934-2940). Denver, CO : IEEE [10.1109/ECCE.2013.6647083].
Bifaretti, S
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/98110
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact