In this paper we illustrate an ongoing project focused on intraoperative monitoring of haemodynamic stability and cardiorespiratory interactions, and present an example analysis of vital signs recorded synchronously from multiple monitoring devices through a LabView©-based acquisition software termed “Global Collect”. We present two moving average models for the black box estimation of the gains of the cardiopulmonary baroreflex control of arterial resistance and of ventricular contractility, based on invasive, continuous measurements of arterial blood pressure and central venous pressure. As a proof-of-concept, we analyze the effects of a fluid-challenge maneuver performed during major surgery, quantifying the mechanisms through which such maneuvers are able to increase cardiac performance and hence enhance venous return. These preliminary results of a pilot case study demonstrate the potential of investigating autonomic nervous system control of circulation under general anesthesia in advancing intraoperative patient monitoring and aiding maintenance of haemodynamic stability in patients undergoing major surgery.

Toschi, N., Canichella, A., Coniglione, F., Sabato, E., Della Badia Giussi, F., Dauri, M., et al. (2010). Intraoperative haemodynamic monitoring: a pilot study on integrated data collection, processing and modelling for extracting vital signs and beyond. In 2010 3rd international symposium on applied sciences in biomedical and communication technologies (ISABEL 2010) (pp.1-5). IEEE [10.1109/ISABEL.2010.5702766].

Intraoperative haemodynamic monitoring: a pilot study on integrated data collection, processing and modelling for extracting vital signs and beyond

TOSCHI, NICOLA;CANICHELLA, ANTONIO;CONIGLIONE, FILADELFO;DAURI, MARIO;SABATO, ALESSANDRO FABRIZIO;GUERRISI, MARIA GIOVANNA;
2010-01-01

Abstract

In this paper we illustrate an ongoing project focused on intraoperative monitoring of haemodynamic stability and cardiorespiratory interactions, and present an example analysis of vital signs recorded synchronously from multiple monitoring devices through a LabView©-based acquisition software termed “Global Collect”. We present two moving average models for the black box estimation of the gains of the cardiopulmonary baroreflex control of arterial resistance and of ventricular contractility, based on invasive, continuous measurements of arterial blood pressure and central venous pressure. As a proof-of-concept, we analyze the effects of a fluid-challenge maneuver performed during major surgery, quantifying the mechanisms through which such maneuvers are able to increase cardiac performance and hence enhance venous return. These preliminary results of a pilot case study demonstrate the potential of investigating autonomic nervous system control of circulation under general anesthesia in advancing intraoperative patient monitoring and aiding maintenance of haemodynamic stability in patients undergoing major surgery.
International symposium on applied sciences in biomedical and communication technologies (ISABEL)
Roma
2010
3.
Rilevanza internazionale
2010
2010
Settore FIS/07 - FISICA APPLICATA (A BENI CULTURALI, AMBIENTALI, BIOLOGIA E MEDICINA)
Settore MED/41 - ANESTESIOLOGIA
English
Anesthesia; Cardiorespiratory interaction; Haemodynamic monitoring; Integrated data; Intra-operative; Intraoperative monitoring; LabViEW; Monitoring device; Non invasive estimation of baroreflex control of circulation; Pilot studies; System identification; Vital sign
Intervento a convegno
Toschi, N., Canichella, A., Coniglione, F., Sabato, E., Della Badia Giussi, F., Dauri, M., et al. (2010). Intraoperative haemodynamic monitoring: a pilot study on integrated data collection, processing and modelling for extracting vital signs and beyond. In 2010 3rd international symposium on applied sciences in biomedical and communication technologies (ISABEL 2010) (pp.1-5). IEEE [10.1109/ISABEL.2010.5702766].
Toschi, N; Canichella, A; Coniglione, F; Sabato, E; Della Badia Giussi, F; Dauri, M; Sabato, Af; Guerrisi, Mg; Ferrario, M; Aletti, F; Signorini, M; B...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/62747
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact