Flexibility, lightness, wearability and cheapness are the most important features for a successful adoption of bend sensors, being they fundamental elements to realize systems able to convert static positions and movements into electrical signals. Even though these sensors have been employed for many different applications, the focal aspect of their mechanical modeling is still not adequately considered. For such a reason the aim of this paper is to fill a lack concerning the method of bend sensors mechanical characterization and modeling. The results have been exploited to realize an instrumented glove able to measure finger joints movements

Saggio, G., Bisegna, P., Latessa, G., Bocchetti, S. (2009). Mechanical modeling of bend sensors exploited to measure human joint movements. ??????? it.cilea.surplus.oa.citation.tipologie.CitationProceedings.prensentedAt ??????? 1th IEEE International WoWMoM Workshop on Interdisciplinary Research on E-Health Services and Systems, IREHSS 2009, Kos (Greece) [10.1109/WOWMOM.2009.5282407].

Mechanical modeling of bend sensors exploited to measure human joint movements

SAGGIO, GIOVANNI;BISEGNA, PAOLO;
2009-06-01

Abstract

Flexibility, lightness, wearability and cheapness are the most important features for a successful adoption of bend sensors, being they fundamental elements to realize systems able to convert static positions and movements into electrical signals. Even though these sensors have been employed for many different applications, the focal aspect of their mechanical modeling is still not adequately considered. For such a reason the aim of this paper is to fill a lack concerning the method of bend sensors mechanical characterization and modeling. The results have been exploited to realize an instrumented glove able to measure finger joints movements
1th IEEE International WoWMoM Workshop on Interdisciplinary Research on E-Health Services and Systems, IREHSS 2009
Kos (Greece)
2009
Rilevanza internazionale
contributo
giu-2009
Settore ING-INF/01 - ELETTRONICA
English
Sensor modeling; mechanical modeling; wearable sensors; non implantable sensors
http://www.pubzone.org/pages/publications/showPublication.do?publicationId=1331139
Intervento a convegno
Saggio, G., Bisegna, P., Latessa, G., Bocchetti, S. (2009). Mechanical modeling of bend sensors exploited to measure human joint movements. ??????? it.cilea.surplus.oa.citation.tipologie.CitationProceedings.prensentedAt ??????? 1th IEEE International WoWMoM Workshop on Interdisciplinary Research on E-Health Services and Systems, IREHSS 2009, Kos (Greece) [10.1109/WOWMOM.2009.5282407].
Saggio, G; Bisegna, P; Latessa, G; Bocchetti, S
File in questo prodotto:
File Dimensione Formato  
1569189123 Mechanical Model.pdf

accesso aperto

Descrizione: Mechanical modeling of bend sensors exploited to measure human joint movements
Dimensione 345.65 kB
Formato Adobe PDF
345.65 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/55463
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 0
social impact