Introduction: Treatment of complex aortic arch pathology in patients with prior cardiac surgery represents a significant challenge, particularly in the setting of high operative risk and associated aortic dissection. The NEXUS Trē Aortic Arch Stent Graft is a custom-made device based on the existing NEXUS® Aortic Arch Stent Graft System (Endospan), a CE-marked endovascular branch system for the aortic arch. It offers a total endovascular, fully percutaneous option — via a low-profile 20F delivery system — that preserves perfusion to all three supra-aortic branches, replicating native arch anatomy and eliminating the need for surgical debranching. Case Presentation: A 77-year-old woman with hypertension, atrial fibrillation, and Alzheimer's disease underwent a total body CT scan in September 2024 following a syncopal episode, which revealed a 63×58 mm ascending aortic aneurysm. She underwent ascending aortic replacement with an Intergard Woven 32 mm graft. During follow-up, progressive dilatation of the aortic arch was noted, evolving into a 56 mm aortic arch aneurysm associated with a type B aortic dissection extending to the aortic bifurcation. Given her comorbidities and the complexity of open re-intervention, the aortic multidisciplinary team recommended a totally endovascular strategy. Via bilateral femoral and brachial access, under angiographic and IVUS guidance, a Gore CTAG thoracic endograft was deployed in the descending thoracic aorta at the site of the type B dissection, and a custom-made NEXUS Trē endograft was implanted in the aortic arch, with stenting of the left common carotid and left subclavian arteries using Gore VBX stents. Graft module deployment was performed under rapid pacing. The three-branch configuration of the NEXUS Trē allowed perfusion of all supra-aortic vessels while replicating native arch anatomy, without need for surgical debranching. Results/Outcome: Completion angiography confirmed patency of the epiaortic and coronary vessels, with exclusion of the aneurysm and thoracic false lumen. Postoperative CT angiography confirmed correct endograft positioning, patency of the supra-aortic branches, and early sac shrinkage with partial thrombosis of the aneurysm sac. The patient had a fast, uneventful recovery and was discharged in good general condition, with no complications and no endoleak. Conclusion: Total endovascular arch repair with the NEXUS Trē system may represent a valid alternative for patients at high risk for open re-intervention following prior cardiac surgery, though it requires careful preoperative planning and expertise in managing potential complications.

Dakli, M., Greco, N., Dionisi, S., De Luca, R., Salvati, A.c., Scognamiglio, M., et al. (2026). Total Endovascular Aortic Arch Replacement with NEXUS Tre Stent Graft System Following Ascending Aortic Repair, in a Patient with Type B Aortic Dissection: A case Report. In Abstract Video (pp.1).

Total Endovascular Aortic Arch Replacement with NEXUS Tre Stent Graft System Following Ascending Aortic Repair, in a Patient with Type B Aortic Dissection: A case Report

Dakli, M;Greco, N;Dionisi, S;De Luca, R;Scognamiglio, M;Oddi, F M;Fazzini S;Martelli E;Nardi, P;
2026-01-01

Abstract

Introduction: Treatment of complex aortic arch pathology in patients with prior cardiac surgery represents a significant challenge, particularly in the setting of high operative risk and associated aortic dissection. The NEXUS Trē Aortic Arch Stent Graft is a custom-made device based on the existing NEXUS® Aortic Arch Stent Graft System (Endospan), a CE-marked endovascular branch system for the aortic arch. It offers a total endovascular, fully percutaneous option — via a low-profile 20F delivery system — that preserves perfusion to all three supra-aortic branches, replicating native arch anatomy and eliminating the need for surgical debranching. Case Presentation: A 77-year-old woman with hypertension, atrial fibrillation, and Alzheimer's disease underwent a total body CT scan in September 2024 following a syncopal episode, which revealed a 63×58 mm ascending aortic aneurysm. She underwent ascending aortic replacement with an Intergard Woven 32 mm graft. During follow-up, progressive dilatation of the aortic arch was noted, evolving into a 56 mm aortic arch aneurysm associated with a type B aortic dissection extending to the aortic bifurcation. Given her comorbidities and the complexity of open re-intervention, the aortic multidisciplinary team recommended a totally endovascular strategy. Via bilateral femoral and brachial access, under angiographic and IVUS guidance, a Gore CTAG thoracic endograft was deployed in the descending thoracic aorta at the site of the type B dissection, and a custom-made NEXUS Trē endograft was implanted in the aortic arch, with stenting of the left common carotid and left subclavian arteries using Gore VBX stents. Graft module deployment was performed under rapid pacing. The three-branch configuration of the NEXUS Trē allowed perfusion of all supra-aortic vessels while replicating native arch anatomy, without need for surgical debranching. Results/Outcome: Completion angiography confirmed patency of the epiaortic and coronary vessels, with exclusion of the aneurysm and thoracic false lumen. Postoperative CT angiography confirmed correct endograft positioning, patency of the supra-aortic branches, and early sac shrinkage with partial thrombosis of the aneurysm sac. The patient had a fast, uneventful recovery and was discharged in good general condition, with no complications and no endoleak. Conclusion: Total endovascular arch repair with the NEXUS Trē system may represent a valid alternative for patients at high risk for open re-intervention following prior cardiac surgery, though it requires careful preoperative planning and expertise in managing potential complications.
Focus on the Cardiac Surgery 2.0
Palermo
2026
Focus on the Cardiac Surgery 2.0
Focus on the Cardiac Surgery 2.0
Rilevanza nazionale
su invito
2026
Settore MED/23
Settore MEDS-13/C - Chirurgia cardiaca
English
Intervento a convegno
Dakli, M., Greco, N., Dionisi, S., De Luca, R., Salvati, A.c., Scognamiglio, M., et al. (2026). Total Endovascular Aortic Arch Replacement with NEXUS Tre Stent Graft System Following Ascending Aortic Repair, in a Patient with Type B Aortic Dissection: A case Report. In Abstract Video (pp.1).
Dakli, M; Greco, N; Dionisi, S; De Luca, R; Salvati, Ac; Scognamiglio, M; Oddi, Fm; Fazzini, S; Martelli, E; Nardi, P; D’Onofrio, A
File in questo prodotto:
File Dimensione Formato  
Totally percutaneous endovascular aortic arch replacement.pdf

solo utenti autorizzati

Tipologia: Documento in Post-print
Licenza: Copyright degli autori
Dimensione 420.53 kB
Formato Adobe PDF
420.53 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/476784
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact