This paper describes a field trial of artificial ground freezing (AGF) carried out in connection with the construction of Line C of Roma underground. AGF was one of the options considered for the temporary stabilisation of the ground during the excavation of Colosseo-Fori Imperiali Station. The field trial aimed at assessing the feasibility of AGF in the complex soil profile and groundwater regime of the subsoil of the historical centre of Roma by establishing the response of the subsoil to the imposed freezing loads, the ability to create a continuous frozen wall, and the associated coolant consumption. The extensive monitoring data were exploited to conduct a detailed analysis of the transient freezing process in the stratified subsoil and used to develop and validate a three-dimensional thermohydraulic numerical model. Special attention was given to defining and applying appropriate boundary conditions at the freezing pipes. The paper discusses the main factors affecting the time-dependent freezing process and explores the applicability of simplified twodimensional models for the Fori Imperiali AGF field trial.
Guida, G., Pucci, A., Romani, E., Viggiani, G., Casini, F. (2025). Interpretation of an artificial ground freezing field trial at Fori Imperiali in Rome. UNDERGROUND SPACE, 23, 89-112 [10.1016/j.undsp.2024.12.006].
Interpretation of an artificial ground freezing field trial at Fori Imperiali in Rome
Guida G.;Pucci A.;Casini F.
2025-01-01
Abstract
This paper describes a field trial of artificial ground freezing (AGF) carried out in connection with the construction of Line C of Roma underground. AGF was one of the options considered for the temporary stabilisation of the ground during the excavation of Colosseo-Fori Imperiali Station. The field trial aimed at assessing the feasibility of AGF in the complex soil profile and groundwater regime of the subsoil of the historical centre of Roma by establishing the response of the subsoil to the imposed freezing loads, the ability to create a continuous frozen wall, and the associated coolant consumption. The extensive monitoring data were exploited to conduct a detailed analysis of the transient freezing process in the stratified subsoil and used to develop and validate a three-dimensional thermohydraulic numerical model. Special attention was given to defining and applying appropriate boundary conditions at the freezing pipes. The paper discusses the main factors affecting the time-dependent freezing process and explores the applicability of simplified twodimensional models for the Fori Imperiali AGF field trial.| File | Dimensione | Formato | |
|---|---|---|---|
|
Guida_et_al_2025_interpretation of an artificial ground freezing field trial at fori imperiali station in rome.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
6.24 MB
Formato
Adobe PDF
|
6.24 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.