This study focuses on the development of a new power supply architecture for an implanted cardiac defibrillator (ICD) and a left ventricular assist device (LVAD). In the proposed solution a transcutaneous wireless power transfer technology (WPT) based on magnetic resonance coupling is adopted assuming an on-body transmitting coil and a subcutaneous receiving coil. With this solution, the percutaneous driveline of the LVAD is eliminated, reducing the risk of infection. The WPT receiver is integrated with the ICD. The proposed power supply using a rechargeable ICD battery allows the LVAD to be continuously powered and the ICD battery to be recharged periodically.

Campi, T., Cruciani, S., Maradei, F., Feliziani, M. (2021). Wireless power supply system for left ventricular assist device and implanted cardiac defibrillator. In 2021 IEEE Wireless Power Transfer Conference (WPTC) (pp.1-4). 345 E 47TH ST, NEW YORK, NY 10017 USA : IEEE [10.1109/WPTC51349.2021.9458163].

Wireless power supply system for left ventricular assist device and implanted cardiac defibrillator

Cruciani S.;
2021-01-01

Abstract

This study focuses on the development of a new power supply architecture for an implanted cardiac defibrillator (ICD) and a left ventricular assist device (LVAD). In the proposed solution a transcutaneous wireless power transfer technology (WPT) based on magnetic resonance coupling is adopted assuming an on-body transmitting coil and a subcutaneous receiving coil. With this solution, the percutaneous driveline of the LVAD is eliminated, reducing the risk of infection. The WPT receiver is integrated with the ICD. The proposed power supply using a rechargeable ICD battery allows the LVAD to be continuously powered and the ICD battery to be recharged periodically.
2021 IEEE Wireless Power Transfer Conference (WPTC)
San Diego, CA, USA
2021
Rilevanza internazionale
2021
Settore ING-IND/31 - ELETTROTECNICA
English
Active implantable medical device (AIMD)
driveline infection (DLI)
implanted cardiac defibrillator (ICD)
left ventricular assist device (LVAD)
transcutaneous energy transfer (TET)
wireless power transfer (WPT)
Intervento a convegno
Campi, T., Cruciani, S., Maradei, F., Feliziani, M. (2021). Wireless power supply system for left ventricular assist device and implanted cardiac defibrillator. In 2021 IEEE Wireless Power Transfer Conference (WPTC) (pp.1-4). 345 E 47TH ST, NEW YORK, NY 10017 USA : IEEE [10.1109/WPTC51349.2021.9458163].
Campi, T; Cruciani, S; Maradei, F; Feliziani, M
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/325210
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 0
social impact