The transient stabilization and voltage regulation problem for a synchronous generator connected to an infinite bus is addressed, in this article, in the presence of all uncertain physical parameters. First, new interpretations for the desensitized four loops regulator, here referred to as robust coordinated power system stabilizer and automatic voltage regulator (PSS-AVR) are derived in terms of minimum phase properties with respect to a suitably chosen output for the linearized error system. Second, on the basis of such an output, a nonlinear generalization of the robust coordinated PSS-AVR is designed with the aim of enlarging the stability region and improving the transients about the unpredictable operating conditions determined by the faults. Its linear action coincides with the one provided by the robust coordinated PSS-AVR: the compelling simplicity of control structure (just one integrator is involved) and robust tuning procedure of the linear design are definitely inherited, with, additionally, no use of the mechanical input power. A numerical analysis, along with realistic simulations, confirms improved stability when the proposed nonlinear controller is applied.

Verrelli, C.m., Marino, R., Tomei, P., Damm, G. (2022). Nonlinear Robust Coordinated PSS-AVR Control for a Synchronous Generator Connected to an Infinite Bus. IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 67(3), 1414-1422 [10.1109/TAC.2021.3062174].

Nonlinear Robust Coordinated PSS-AVR Control for a Synchronous Generator Connected to an Infinite Bus

Verrelli C. M.
;
Marino R.;Tomei P.;
2022-01-01

Abstract

The transient stabilization and voltage regulation problem for a synchronous generator connected to an infinite bus is addressed, in this article, in the presence of all uncertain physical parameters. First, new interpretations for the desensitized four loops regulator, here referred to as robust coordinated power system stabilizer and automatic voltage regulator (PSS-AVR) are derived in terms of minimum phase properties with respect to a suitably chosen output for the linearized error system. Second, on the basis of such an output, a nonlinear generalization of the robust coordinated PSS-AVR is designed with the aim of enlarging the stability region and improving the transients about the unpredictable operating conditions determined by the faults. Its linear action coincides with the one provided by the robust coordinated PSS-AVR: the compelling simplicity of control structure (just one integrator is involved) and robust tuning procedure of the linear design are definitely inherited, with, additionally, no use of the mechanical input power. A numerical analysis, along with realistic simulations, confirms improved stability when the proposed nonlinear controller is applied.
2022
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore ING-INF/04 - AUTOMATICA
English
Voltage control
Transient analysis
Power system stability
Synchronous generators
Stability analysis
Generators
Regulators
Nonlinear control
robust coordinated PSS-AVR
synchronous generators
transient stability
voltage regulation
Verrelli, C.m., Marino, R., Tomei, P., Damm, G. (2022). Nonlinear Robust Coordinated PSS-AVR Control for a Synchronous Generator Connected to an Infinite Bus. IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 67(3), 1414-1422 [10.1109/TAC.2021.3062174].
Verrelli, Cm; Marino, R; Tomei, P; Damm, G
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/312802
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 5
social impact