In this work a method is proposed to estimate the effect of indoor microclimate on the risk of degradation of ancient materials stored in historical buildings. The method, which combines microclimate observations and dynamic simulation, has shown to be strategic in preventive conservation of historical buildings. Indeed, once the building model is calibrated, it can be effectively used for evaluating the microclimate control solutions on the conservation reducing general degradation risks. The method has been applied to a historical building close to Rome, where deteriorations in ceilings occurred and visitors complain about thermal discomfort. First, the HVAC system in the model has set in order to guarantee both thermal comfort and adequate condition for the conservation of the material. Then, the crack width of wooden ceiling has been estimated by means of an empirical model based on indoor temperature and relative humidity data and validated with the measurements of the crack width. It was found a reduction of annual variation from 0.4 mm to 0.2 mm, experimented by panels, and an improvement of maximum daily variation, especially in winter and summer (less than 0.01 mm on average).

Frasca, F., Cornaro, C., Maria Siani, A. (2018). A method for an effective microclimate management in historical buildings combining monitoring and dynamic simulation: the case of “Museo Archeologico di Priverno”. In Proceedings of 7th International Building Physics Conference, IBPC2018.

A method for an effective microclimate management in historical buildings combining monitoring and dynamic simulation: the case of “Museo Archeologico di Priverno”

Cristina Cornaro;
2018-01-01

Abstract

In this work a method is proposed to estimate the effect of indoor microclimate on the risk of degradation of ancient materials stored in historical buildings. The method, which combines microclimate observations and dynamic simulation, has shown to be strategic in preventive conservation of historical buildings. Indeed, once the building model is calibrated, it can be effectively used for evaluating the microclimate control solutions on the conservation reducing general degradation risks. The method has been applied to a historical building close to Rome, where deteriorations in ceilings occurred and visitors complain about thermal discomfort. First, the HVAC system in the model has set in order to guarantee both thermal comfort and adequate condition for the conservation of the material. Then, the crack width of wooden ceiling has been estimated by means of an empirical model based on indoor temperature and relative humidity data and validated with the measurements of the crack width. It was found a reduction of annual variation from 0.4 mm to 0.2 mm, experimented by panels, and an improvement of maximum daily variation, especially in winter and summer (less than 0.01 mm on average).
7th International Building Physics Conference, IBPC2018
Syracuse (NY) USA
2018
7
Rilevanza internazionale
contributo
2018
Settore ING-IND/11 - FISICA TECNICA AMBIENTALE
English
Historical building; microclimate; conservation strategy; dynamic simulation
Intervento a convegno
Frasca, F., Cornaro, C., Maria Siani, A. (2018). A method for an effective microclimate management in historical buildings combining monitoring and dynamic simulation: the case of “Museo Archeologico di Priverno”. In Proceedings of 7th International Building Physics Conference, IBPC2018.
Frasca, F; Cornaro, C; Maria Siani, A
File in questo prodotto:
File Dimensione Formato  
articolo_proceedings.pdf

solo utenti autorizzati

Licenza: Copyright dell'editore
Dimensione 626.05 kB
Formato Adobe PDF
626.05 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/207021
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact