In this work a method is proposed to estimate the effect of indoor microclimate on the risk of degradation of ancient materials stored in historical buildings. The method, which combines microclimate observations and dynamic simulation, has shown to be strategic in preventive conservation of historical buildings. Indeed, once the building model is calibrated, it can be effectively used for evaluating the microclimate control solutions on the conservation reducing general degradation risks. The method has been applied to a historical building close to Rome, where deteriorations in ceilings occurred and visitors complain about thermal discomfort. First, the HVAC system in the model has set in order to guarantee both thermal comfort and adequate condition for the conservation of the material. Then, the crack width of wooden ceiling has been estimated by means of an empirical model based on indoor temperature and relative humidity data and validated with the measurements of the crack width. It was found a reduction of annual variation from 0.4 mm to 0.2 mm, experimented by panels, and an improvement of maximum daily variation, especially in winter and summer (less than 0.01 mm on average).
Frasca, F., Cornaro, C., Maria Siani, A. (2018). A method for an effective microclimate management in historical buildings combining monitoring and dynamic simulation: the case of “Museo Archeologico di Priverno”. In Proceedings of 7th International Building Physics Conference, IBPC2018.
A method for an effective microclimate management in historical buildings combining monitoring and dynamic simulation: the case of “Museo Archeologico di Priverno”
Cristina Cornaro;
2018-01-01
Abstract
In this work a method is proposed to estimate the effect of indoor microclimate on the risk of degradation of ancient materials stored in historical buildings. The method, which combines microclimate observations and dynamic simulation, has shown to be strategic in preventive conservation of historical buildings. Indeed, once the building model is calibrated, it can be effectively used for evaluating the microclimate control solutions on the conservation reducing general degradation risks. The method has been applied to a historical building close to Rome, where deteriorations in ceilings occurred and visitors complain about thermal discomfort. First, the HVAC system in the model has set in order to guarantee both thermal comfort and adequate condition for the conservation of the material. Then, the crack width of wooden ceiling has been estimated by means of an empirical model based on indoor temperature and relative humidity data and validated with the measurements of the crack width. It was found a reduction of annual variation from 0.4 mm to 0.2 mm, experimented by panels, and an improvement of maximum daily variation, especially in winter and summer (less than 0.01 mm on average).File | Dimensione | Formato | |
---|---|---|---|
articolo_proceedings.pdf
solo utenti autorizzati
Licenza:
Copyright dell'editore
Dimensione
626.05 kB
Formato
Adobe PDF
|
626.05 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.