In the paper the uncertainty analysis of the FTA Lab ESTER facility instrumentation is presented together with the procedure used to validate data outputs through measurements on a reference polycrystalline module provided by ISAAC-SUPSI. The reference module has been tested for several months and a procedure has been identified to sort the IV curves for translation at STC conditions. Blaesser method has been implemented and comparison between STC data from indoor measurements by ISAAC and translated outdoor curves produced quite satisfactory results.
Spena, A., Cornaro, C., Intreccialagli, G., Chianese, D. (2009). Data validation and uncertainty evaluation of the ESTER outdoor facility for testing of PV modules. In Proceedings of the 24th European photovoltaic solar energy conference and exhibition / eds. W. Sinke, H. Ossenbrink, P. Helm (pp.3586). WIP - Renewable Energies.
Data validation and uncertainty evaluation of the ESTER outdoor facility for testing of PV modules
SPENA, ANGELO;CORNARO, CRISTINA;
2009-01-01
Abstract
In the paper the uncertainty analysis of the FTA Lab ESTER facility instrumentation is presented together with the procedure used to validate data outputs through measurements on a reference polycrystalline module provided by ISAAC-SUPSI. The reference module has been tested for several months and a procedure has been identified to sort the IV curves for translation at STC conditions. Blaesser method has been implemented and comparison between STC data from indoor measurements by ISAAC and translated outdoor curves produced quite satisfactory results.File | Dimensione | Formato | |
---|---|---|---|
4AV.3.89_paper.pdf
accesso aperto
Descrizione: articolo
Licenza:
Creative commons
Dimensione
316.07 kB
Formato
Adobe PDF
|
316.07 kB | Adobe PDF | Visualizza/Apri |