Abstract Introduction: The purpose of this study was to evaluate the effectiveness of different irrigating methods in removing the smear layer at 1, 3, 5, and 8 mm from the apex of endodontic canals. Methods: Sixty-five extracted single-rooted human mandibular premolars were decoronated to a standardized length of 16 mm. Specimens were shaped to ProTaper F4 (Dentsply Maillefer, Ballaigues, Switzerland) and irrigated with 5.25% NaOCl at 37 C. Teeth were divided into 5 groups (2 control groups [n = 10] and 3 test groups [n = 15]) according to the final irrigant activation/delivering technique (ie, sonic irrigation, passive ultrasonic irrigation [PUI], or apical negative pressure). Root canals were then split longitudinally and observed by field emission scanning electron microscopy. The presence of debris and a smear layer at 1, 3, 5, and 8 mm from the apex was evaluated. Scores were analyzed by Kruskal- Wallis and Mann-Whitney U tests. Results: The EndoActivator System (Dentsply Tulsa Dental Specialties, Tulsa, OK) was significantly more efficient than PUI and the control groups in removing the smear layer at 3, 5, and 8 mm from the apex. The EndoVac System (Discus Dental, Culver City, CA) removed statistically significantly more smear layer than all groups at 1, 3, 5, and 8 mm from the apex. At 5 and 8 mm from the apex, PUI and the EndoVac did not differ statistically significantly, but both performed statistically better than the control groups. Conclusions: In our study, none of the activation/delivery systems completely removed the smear layer from the endodontic dentine walls; nevertheless, the EndoActivator and EndoVac showed the best results at 3, 5, and 8 mm (EndoActivator) and 1, 3, 5, and 8 mm (EndoVac) from the apex. (J Endod 2013;39:1456–1460)

Mancini, M., Cerroni, L., Iorio, L., Armellin, E., Conte, G., Cianconi, L. (2013). Smear layer removal and canal cleanliness using different irrigation systems (EndoActivator, EndoVac, and Passive Ultrasonic Irrigation) : Field Emission Scanning Electron Microscopic Evaluation in an In Vitro Study. JOURNAL OF ENDODONTICS, 39(5), 1456-1460.

Smear layer removal and canal cleanliness using different irrigation systems (EndoActivator, EndoVac, and Passive Ultrasonic Irrigation) : Field Emission Scanning Electron Microscopic Evaluation in an In Vitro Study.

CIANCONI, LUIGI
2013-11-01

Abstract

Abstract Introduction: The purpose of this study was to evaluate the effectiveness of different irrigating methods in removing the smear layer at 1, 3, 5, and 8 mm from the apex of endodontic canals. Methods: Sixty-five extracted single-rooted human mandibular premolars were decoronated to a standardized length of 16 mm. Specimens were shaped to ProTaper F4 (Dentsply Maillefer, Ballaigues, Switzerland) and irrigated with 5.25% NaOCl at 37 C. Teeth were divided into 5 groups (2 control groups [n = 10] and 3 test groups [n = 15]) according to the final irrigant activation/delivering technique (ie, sonic irrigation, passive ultrasonic irrigation [PUI], or apical negative pressure). Root canals were then split longitudinally and observed by field emission scanning electron microscopy. The presence of debris and a smear layer at 1, 3, 5, and 8 mm from the apex was evaluated. Scores were analyzed by Kruskal- Wallis and Mann-Whitney U tests. Results: The EndoActivator System (Dentsply Tulsa Dental Specialties, Tulsa, OK) was significantly more efficient than PUI and the control groups in removing the smear layer at 3, 5, and 8 mm from the apex. The EndoVac System (Discus Dental, Culver City, CA) removed statistically significantly more smear layer than all groups at 1, 3, 5, and 8 mm from the apex. At 5 and 8 mm from the apex, PUI and the EndoVac did not differ statistically significantly, but both performed statistically better than the control groups. Conclusions: In our study, none of the activation/delivery systems completely removed the smear layer from the endodontic dentine walls; nevertheless, the EndoActivator and EndoVac showed the best results at 3, 5, and 8 mm (EndoActivator) and 1, 3, 5, and 8 mm (EndoVac) from the apex. (J Endod 2013;39:1456–1460)
nov-2013
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE
English
EndoActivator System; EndoVac System; field emission scanning electron microscopy; irrigant activation; passive ultrasonic irrigation; smear layer;
Mancini, M., Cerroni, L., Iorio, L., Armellin, E., Conte, G., Cianconi, L. (2013). Smear layer removal and canal cleanliness using different irrigation systems (EndoActivator, EndoVac, and Passive Ultrasonic Irrigation) : Field Emission Scanning Electron Microscopic Evaluation in an In Vitro Study. JOURNAL OF ENDODONTICS, 39(5), 1456-1460.
Mancini, M; Cerroni, L; Iorio, L; Armellin, E; Conte, G; Cianconi, L
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
JOE-39-11-1456.pdf

accesso aperto

Descrizione: Articolo Fulltext
Dimensione 950.27 kB
Formato Adobe PDF
950.27 kB Adobe PDF Visualizza/Apri