Lipase activity against triacylglycerols has been measured using an amperometric enzyme biosensor based on glycerol dehydrogenase/NADH oxidase. A Prussian Blue modified screen-printed electrode was selected as substrate for the two immobilised-enzyme systems due to their higher operative stability reported in previous works. Various parameters such as cofactor (flavin mononucleotide FMN) concentration (1 mM), NAD+ coenzyme concentration (2 mM), pH effect (phosphate buffer pH 6 to 8, Tris buffer pH 8–10) response time and storage stability were evaluated and optimised. The glycerol biosensor was then investigated for lipase activity. The system was challenged against an olive or sunflower oil real samples in order to detect fatty acids and the results were compared with those provided either by the manufacture or reference methods with good agreement.

Ben Rejeb, I., Arduini, F., A, A., Gargouri, M., Palleschi, G. (2007). Amperometric biosensor based on Prussian Blue-modified screen printed electrode for lipase activity and triacylglycerol determination. ANALYTICA CHIMICA ACTA, 594, 1-8 [10.1016/j.aca.2007.04.066].

Amperometric biosensor based on Prussian Blue-modified screen printed electrode for lipase activity and triacylglycerol determination

ARDUINI, FABIANA;PALLESCHI, GIUSEPPE
2007-01-01

Abstract

Lipase activity against triacylglycerols has been measured using an amperometric enzyme biosensor based on glycerol dehydrogenase/NADH oxidase. A Prussian Blue modified screen-printed electrode was selected as substrate for the two immobilised-enzyme systems due to their higher operative stability reported in previous works. Various parameters such as cofactor (flavin mononucleotide FMN) concentration (1 mM), NAD+ coenzyme concentration (2 mM), pH effect (phosphate buffer pH 6 to 8, Tris buffer pH 8–10) response time and storage stability were evaluated and optimised. The glycerol biosensor was then investigated for lipase activity. The system was challenged against an olive or sunflower oil real samples in order to detect fatty acids and the results were compared with those provided either by the manufacture or reference methods with good agreement.
2007
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/01 - CHIMICA ANALITICA
English
Con Impact Factor ISI
Ben Rejeb, I., Arduini, F., A, A., Gargouri, M., Palleschi, G. (2007). Amperometric biosensor based on Prussian Blue-modified screen printed electrode for lipase activity and triacylglycerol determination. ANALYTICA CHIMICA ACTA, 594, 1-8 [10.1016/j.aca.2007.04.066].
Ben Rejeb, I; Arduini, F; A, A; Gargouri, M; Palleschi, G
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/99508
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 45
social impact