A plastic scintillating disc (NE 102, 3 cm thick, 1 m diameter) has been designed for detecting charged pions in nuclear reactions at intermediate energy. A hole of 20 cm diameter was made in the middle of the dise in order to allow for the beam passage through the detector. The originality of the detector consists of the simultaneous use of foul very compact central Photo Multiplier Tubes (PMT) and eight peripheral PMTs in order to retrieve the hitting point of a charged particle onto the disc surface with a space resolution of +/- 3 cm. The original method has been developed by using polar coordinates and only the Time-Of-Flight information (TOF) from three or four nearest PMTs, including at least one central PMT. (C) 2001 Published by Elsevier Science B.V.

Bellini, V., Palazzolo, F., Scire, A., Sperduto, M., Albergo, S., Poli, G., et al. (2001). Position sensitive disc for charged particle detection. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 461, 174-177 [10.1016/S0168-9002(00)01199-2].

Position sensitive disc for charged particle detection

SCHAERF, CARLO;D'ANGELO, ANNALISA;
2001-01-01

Abstract

A plastic scintillating disc (NE 102, 3 cm thick, 1 m diameter) has been designed for detecting charged pions in nuclear reactions at intermediate energy. A hole of 20 cm diameter was made in the middle of the dise in order to allow for the beam passage through the detector. The originality of the detector consists of the simultaneous use of foul very compact central Photo Multiplier Tubes (PMT) and eight peripheral PMTs in order to retrieve the hitting point of a charged particle onto the disc surface with a space resolution of +/- 3 cm. The original method has been developed by using polar coordinates and only the Time-Of-Flight information (TOF) from three or four nearest PMTs, including at least one central PMT. (C) 2001 Published by Elsevier Science B.V.
2001
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore FIS/04 - FISICA NUCLEARE E SUBNUCLEARE
English
Con Impact Factor ISI
http://www.sciencedirect.com/science/article/pii/S0168900200011992
Bellini, V., Palazzolo, F., Scire, A., Sperduto, M., Albergo, S., Poli, G., et al. (2001). Position sensitive disc for charged particle detection. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 461, 174-177 [10.1016/S0168-9002(00)01199-2].
Bellini, V; Palazzolo, F; Scire, A; Sperduto, M; Albergo, S; Poli, G; Potenza, R; Randieri, C; Russo, V; Sutera, M; Capogni, M; Schaerf, C; D'Angelo, ...espandi
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/95396
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact