Segmentation of the breast region is a fundamental step in any system for computerized analysis of mammograms. In this work, we propose a novel procedure for the estimation of the breast skin-line based upon multidirectional Gabor filtering. The method includes an adaptive values-of-interest(VOI) transformation, extraction of the skin–air ribbon by Otsu's thresholding method and the Euclidean distance transform, Gabor filtering with 18 real kernels, and a step for suppression of false edge points using the magnitude and phase responses of the filters. On a test set of 361 images from different acquisition modalities (screen-film and full-field digital mammograms),the average Hausdorff and polyline distances obtained were 2.85 mm and 0.84 mm, respectively, with reference to the ground-truth boundaries provided by an expert radiologist. When compared with the results obtained by other state-of-the-art methods on the same set of images and with respect to the same ground-truth boundaries, our method mostly outperformed the other approaches. The results demonstrate the effectiveness and robustness of the proposed algorithm.

Casti, P., Mencattini, A., Salmeri, M., Ancona, A., Mangeri, F., Pepe, M., et al. (2013). Estimation of the breast skin-line in mammograms using multidirectional Gabor filters. COMPUTERS IN BIOLOGY AND MEDICINE, 43(11), 1870-1881 [10.1016/j.compbiomed.2013.09.001].

Estimation of the breast skin-line in mammograms using multidirectional Gabor filters

Casti, P;MENCATTINI, ARIANNA;SALMERI, MARCELLO;
2013-11-01

Abstract

Segmentation of the breast region is a fundamental step in any system for computerized analysis of mammograms. In this work, we propose a novel procedure for the estimation of the breast skin-line based upon multidirectional Gabor filtering. The method includes an adaptive values-of-interest(VOI) transformation, extraction of the skin–air ribbon by Otsu's thresholding method and the Euclidean distance transform, Gabor filtering with 18 real kernels, and a step for suppression of false edge points using the magnitude and phase responses of the filters. On a test set of 361 images from different acquisition modalities (screen-film and full-field digital mammograms),the average Hausdorff and polyline distances obtained were 2.85 mm and 0.84 mm, respectively, with reference to the ground-truth boundaries provided by an expert radiologist. When compared with the results obtained by other state-of-the-art methods on the same set of images and with respect to the same ground-truth boundaries, our method mostly outperformed the other approaches. The results demonstrate the effectiveness and robustness of the proposed algorithm.
nov-2013
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore ING-INF/07 - MISURE ELETTRICHE ED ELETTRONICHE
English
Con Impact Factor ISI
Breast boundary Breast imaging Breast skin-line Computer-aideddetection Digital mammography Gabor filtering Segmentation
http://www.sciencedirect.com/science/article/pii/S0010482513002527
Casti, P., Mencattini, A., Salmeri, M., Ancona, A., Mangeri, F., Pepe, M., et al. (2013). Estimation of the breast skin-line in mammograms using multidirectional Gabor filters. COMPUTERS IN BIOLOGY AND MEDICINE, 43(11), 1870-1881 [10.1016/j.compbiomed.2013.09.001].
Casti, P; Mencattini, A; Salmeri, M; Ancona, A; Mangeri, F; Pepe, M; Rangayyan, R
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0010482513002527-main.pdf

solo utenti autorizzati

Descrizione: Articolo principale
Licenza: Copyright dell'editore
Dimensione 3 MB
Formato Adobe PDF
3 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/94955
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 29
social impact