Detection of oligoclonal IgG bands in cerebrospinal fluid by isoelectrocfocusing and immunodetection is the current gold standard to detect an inflammatory process in the central nervous system. It has been proposed that the presence of free light chains (FLCs) in CSF was associated with recent demyelination activity in MS and might be used as a prognosis marker. Our study’s objective is assessing the diagnostic accuracy of a new highly sensitive latex-enhanced nephelometric assay for k free light chain (kFLC) determination in CSF/serum as an alternative to traditional tests and its clinical application. Methods. kFLCs were measured in CSF/serum pairs from 80 patients by the use of a new highly sensitive latex-enhanced nephelometric automated immunoassay for detection of immunoglobulin FLC. The eighty patients were split into three groups according to the neurological diagnosis. In this study we confirm even more the use of the k Index as a diagnostic aid in multiple sclerosis. Results. kFLC Index seems to be more accurate parameter respect the determination of oligoclonal immunoglobulin bands (OCBs). We recalculate the K Index sensitivity and specificity respect the precedent published result. Two patients previously diagnosed with leukoencephalopathy have gone to group 3 as confirmed the diagnosis of MS. Conclusions. These new data reinforce even more the use of the k Index to diagnose MS in comparison to classical methods and to the reference method, the OCBs.
Pieri, M., Duranti, F., Centonze, D., Buttari, F., Bernardini, S., Dessi', M. (2014). K Index in cerebrospinal fluid: a valid tool in multiple sclerosis diagnosis. LA RIVISTA ITALIANA DELLA MEDICINA DI LABORATORIO [10.1007/s13631-014-0072-0].
K Index in cerebrospinal fluid: a valid tool in multiple sclerosis diagnosis
Pieri,M;CENTONZE, DIEGO;BERNARDINI, SERGIO;DESSI', MARIARITA
2014-09-23
Abstract
Detection of oligoclonal IgG bands in cerebrospinal fluid by isoelectrocfocusing and immunodetection is the current gold standard to detect an inflammatory process in the central nervous system. It has been proposed that the presence of free light chains (FLCs) in CSF was associated with recent demyelination activity in MS and might be used as a prognosis marker. Our study’s objective is assessing the diagnostic accuracy of a new highly sensitive latex-enhanced nephelometric assay for k free light chain (kFLC) determination in CSF/serum as an alternative to traditional tests and its clinical application. Methods. kFLCs were measured in CSF/serum pairs from 80 patients by the use of a new highly sensitive latex-enhanced nephelometric automated immunoassay for detection of immunoglobulin FLC. The eighty patients were split into three groups according to the neurological diagnosis. In this study we confirm even more the use of the k Index as a diagnostic aid in multiple sclerosis. Results. kFLC Index seems to be more accurate parameter respect the determination of oligoclonal immunoglobulin bands (OCBs). We recalculate the K Index sensitivity and specificity respect the precedent published result. Two patients previously diagnosed with leukoencephalopathy have gone to group 3 as confirmed the diagnosis of MS. Conclusions. These new data reinforce even more the use of the k Index to diagnose MS in comparison to classical methods and to the reference method, the OCBs.File | Dimensione | Formato | |
---|---|---|---|
KIndex Simel.pdf
accesso aperto
Descrizione: articolo
Dimensione
613.94 kB
Formato
Adobe PDF
|
613.94 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.