Introduction: The purpose of this study was to evaluate the effectiveness of different irrigating methods in removing the smear layer at 1, 3, 5, and 8 mm from the apex of endodontic canals. Methods: Sixty-five extracted single-rooted human mandibular premolars were decoronated to a standardized length of 16 mm. Specimens were shaped to ProTaper F4 (Dentsply Maillefer, Ballaigues, Switzerland) and irrigated with 5.25% NaOCl at 37C. Teeth were divided into 5 groups (2 control groups [n = 10] and 3 test groups [n = 15]) according to the final irrigant activation/delivering technique (ie, sonic irrigation, passive ultrasonic irrigation [PUI], or apical negative pressure). Root canals were then split longitudinally and observed by field emission scanning electron microscopy. The presence of debris and a smear layer at 1, 3, 5, and 8 mm from the apex was evaluated. Scores were analyzed by Kruskal- Wallis and Mann-Whitney U tests. Results: The EndoActivator System (Dentsply Tulsa Dental Specialties, Tulsa, OK) was significantly more efficient than PUI and the control groups in removing the smear layer at 3, 5, and 8 mm from the apex. The EndoVac System (Discus Dental, Culver City, CA) removed statistically significantly more smear layer than all groups at 1, 3, 5, and 8 mm from the apex. At 5 and 8 mm from the apex, PUI and the EndoVac did not differ statistically significantly, but both performed statistically better than the control groups. Conclusions: In our study, none of the activation/delivery systems completely removed the smear layer from the endodontic dentine walls; nevertheless, the EndoActivator and EndoVac showed the best results at 3, 5, and 8 mm (EndoActivator) and 1, 3, 5, and 8 mm (EndoVac) from the apex.

Mancini, M., Cerroni, L., Iorio, L., Armellin, E., Conte, G., Cianconi, L. (2013). Smear layer removal and canal cleanliness using different irrigation systems (EndoActivator, EndoVac, and passive ultrasonic irrigation): field emission scanning electron microscopic evaluation in an in vitro study. JOURNAL OF ENDODONTICS, 39(11), 1456-1460 [10.1016/j.joen.2013.07.028].

Smear layer removal and canal cleanliness using different irrigation systems (EndoActivator, EndoVac, and passive ultrasonic irrigation): field emission scanning electron microscopic evaluation in an in vitro study

CERRONI, LOREDANA;CIANCONI, LUIGI
2013-01-01

Abstract

Introduction: The purpose of this study was to evaluate the effectiveness of different irrigating methods in removing the smear layer at 1, 3, 5, and 8 mm from the apex of endodontic canals. Methods: Sixty-five extracted single-rooted human mandibular premolars were decoronated to a standardized length of 16 mm. Specimens were shaped to ProTaper F4 (Dentsply Maillefer, Ballaigues, Switzerland) and irrigated with 5.25% NaOCl at 37C. Teeth were divided into 5 groups (2 control groups [n = 10] and 3 test groups [n = 15]) according to the final irrigant activation/delivering technique (ie, sonic irrigation, passive ultrasonic irrigation [PUI], or apical negative pressure). Root canals were then split longitudinally and observed by field emission scanning electron microscopy. The presence of debris and a smear layer at 1, 3, 5, and 8 mm from the apex was evaluated. Scores were analyzed by Kruskal- Wallis and Mann-Whitney U tests. Results: The EndoActivator System (Dentsply Tulsa Dental Specialties, Tulsa, OK) was significantly more efficient than PUI and the control groups in removing the smear layer at 3, 5, and 8 mm from the apex. The EndoVac System (Discus Dental, Culver City, CA) removed statistically significantly more smear layer than all groups at 1, 3, 5, and 8 mm from the apex. At 5 and 8 mm from the apex, PUI and the EndoVac did not differ statistically significantly, but both performed statistically better than the control groups. Conclusions: In our study, none of the activation/delivery systems completely removed the smear layer from the endodontic dentine walls; nevertheless, the EndoActivator and EndoVac showed the best results at 3, 5, and 8 mm (EndoActivator) and 1, 3, 5, and 8 mm (EndoVac) from the apex.
2013
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE
English
Con Impact Factor ISI
Mancini, M., Cerroni, L., Iorio, L., Armellin, E., Conte, G., Cianconi, L. (2013). Smear layer removal and canal cleanliness using different irrigation systems (EndoActivator, EndoVac, and passive ultrasonic irrigation): field emission scanning electron microscopic evaluation in an in vitro study. JOURNAL OF ENDODONTICS, 39(11), 1456-1460 [10.1016/j.joen.2013.07.028].
Mancini, M; Cerroni, L; Iorio, L; Armellin, E; Conte, G; Cianconi, L
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
JOE2013.pdf

solo utenti autorizzati

Descrizione: articolo principale
Licenza: Copyright dell'editore
Dimensione 950.27 kB
Formato Adobe PDF
950.27 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/90414
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 115
  • ???jsp.display-item.citation.isi??? 81
social impact