The aim of this work was to determine whether the use of a newly developed methodology (Alg1) for AV and VV optimization improves cardiac resynchronization therapy (CRT) clinical and echocardiographic (ECHO) outcomes. In this single-center pilot clinical trial, 80 consecutive patients (79 % male; 70.1 ± 11.2 years) receiving CRT were randomly assigned to AV and VV optimization using Alg1 (group A) or standard commercial procedures (group B). Clinical status and ECHOs were analyzed at baseline (_0) , 3 (fu1), and 6 months (fu2) of follow-up evaluating left ventricular end systolic (LVESV) and end diastolic (LVEDV) volumes, ejection fraction (EF), Minnesota test, and 6-min walk test (6MWT). Alg1 is based on a cardiovascular model fed with patient data. Baseline characteristics did not differ significantly between groups. Group A had a better clinical outcome and reverse remodeling. Remodeling was calculated as the difference (Δ) between fu1 and _0 and between fu2 and fu1, respectively: [LVESV (ml): ΔA_fu1 = -55.3, ΔB_fu1 = -13.5, p_fu1 = 0.002; ΔA_fu2 = -22.8, ΔB_fu2 = 3.0, p_fu2 = 0.04], [LVEDV (ml): ΔA_fu1 = -61.9, ΔB_fu1 = -16.1, p_fu1 = 0.01; ΔA_fu2 = -30.4, ΔB_fu2 = 11.3, p_fu2 = 0.02]; Minnesota test: total (p_fu1 = 0.01; p_fu2 = 0.04), physical (p_fu1 = 0.01; p_fu2 = 0.03) and emotional scores (p_fu1 = 0.04; p_fu2 = 0.03) and in 6MWT (m) (p_fu2 = 0.008). No statistically significant difference was observed in QRS width. Compared with current standard of care, CRT optimization using Alg1 is associated with better outcomes, showing the power of a tailored CRT.
Di Molfetta, A., Forleo, G., Santini, L., Fresiello, L., Papavasileiou, L., Magliano, G., et al. (2013). A novel methodology for AV and VV delay optimization in CRT: results from a randomized pilot clinical trial. JOURNAL OF ARTIFICIAL ORGANS, 35(2), 107-110 [10.1007/s10047-013-0701-9].
A novel methodology for AV and VV delay optimization in CRT: results from a randomized pilot clinical trial
SERGI, DOMENICO;CAPRIA, AMBROGIO;ROMEO, FRANCESCO;
2013-03-16
Abstract
The aim of this work was to determine whether the use of a newly developed methodology (Alg1) for AV and VV optimization improves cardiac resynchronization therapy (CRT) clinical and echocardiographic (ECHO) outcomes. In this single-center pilot clinical trial, 80 consecutive patients (79 % male; 70.1 ± 11.2 years) receiving CRT were randomly assigned to AV and VV optimization using Alg1 (group A) or standard commercial procedures (group B). Clinical status and ECHOs were analyzed at baseline (_0) , 3 (fu1), and 6 months (fu2) of follow-up evaluating left ventricular end systolic (LVESV) and end diastolic (LVEDV) volumes, ejection fraction (EF), Minnesota test, and 6-min walk test (6MWT). Alg1 is based on a cardiovascular model fed with patient data. Baseline characteristics did not differ significantly between groups. Group A had a better clinical outcome and reverse remodeling. Remodeling was calculated as the difference (Δ) between fu1 and _0 and between fu2 and fu1, respectively: [LVESV (ml): ΔA_fu1 = -55.3, ΔB_fu1 = -13.5, p_fu1 = 0.002; ΔA_fu2 = -22.8, ΔB_fu2 = 3.0, p_fu2 = 0.04], [LVEDV (ml): ΔA_fu1 = -61.9, ΔB_fu1 = -16.1, p_fu1 = 0.01; ΔA_fu2 = -30.4, ΔB_fu2 = 11.3, p_fu2 = 0.02]; Minnesota test: total (p_fu1 = 0.01; p_fu2 = 0.04), physical (p_fu1 = 0.01; p_fu2 = 0.03) and emotional scores (p_fu1 = 0.04; p_fu2 = 0.03) and in 6MWT (m) (p_fu2 = 0.008). No statistically significant difference was observed in QRS width. Compared with current standard of care, CRT optimization using Alg1 is associated with better outcomes, showing the power of a tailored CRT.File | Dimensione | Formato | |
---|---|---|---|
jao273.pdf
solo utenti autorizzati
Licenza:
Copyright dell'editore
Dimensione
452.97 kB
Formato
Adobe PDF
|
452.97 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.