Standard anode supported micro tubular-solid oxide fuel cell (MT-SOFC) stacks may provide the oxidant, in relation to the fuel, in three different manifold regimes. Firstly, “co-flow” involves oxidant outside the MT-SOFC flowing co-linearly in relation to the fuel inside. Secondly, “counter flow” involves oxidant outside the MT-SOFC flowing counter-linearly in relation to the fuel inside the MT-SOFC. Finally, “cross-flow” involves the oxidant outside the MT-SOFC flowing perpendicular to the fuel flow inside the MT-SOFC. In order to examine the effect of manifold technique on MT-SOFC performance, a combination of numerical simulation and experimental measurements was performed. Furthermore, the cathode current tap location, in relation to the fuel flow, was also studied. It was found that the oxidant manifold and the location of the cathode current collection point on the MT-SOFC tested and modeled had negligible effect on the MT-SOFC’s electrical and thermal performance. In this study, a single MT-SOFC was studied in order to establish the measurement technique and numerical simulation implementation as a prerequisite before further test involving a 7 cell MT-SOFC stack.

Lawlor, V., Klein, K., Hochenauer, C., Griesser, S., Kuehn, S., Olabi, A., et al. (2013). Experimental and Numerical Study of Various MT-SOFC Flow Manifold Techniques: Single MT-SOFC Analysis. JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 10(1), 011003 [10.1115/1.4023216].

Experimental and Numerical Study of Various MT-SOFC Flow Manifold Techniques: Single MT-SOFC Analysis

CORDINER, STEFANO;
2013-02-01

Abstract

Standard anode supported micro tubular-solid oxide fuel cell (MT-SOFC) stacks may provide the oxidant, in relation to the fuel, in three different manifold regimes. Firstly, “co-flow” involves oxidant outside the MT-SOFC flowing co-linearly in relation to the fuel inside. Secondly, “counter flow” involves oxidant outside the MT-SOFC flowing counter-linearly in relation to the fuel inside the MT-SOFC. Finally, “cross-flow” involves the oxidant outside the MT-SOFC flowing perpendicular to the fuel flow inside the MT-SOFC. In order to examine the effect of manifold technique on MT-SOFC performance, a combination of numerical simulation and experimental measurements was performed. Furthermore, the cathode current tap location, in relation to the fuel flow, was also studied. It was found that the oxidant manifold and the location of the cathode current collection point on the MT-SOFC tested and modeled had negligible effect on the MT-SOFC’s electrical and thermal performance. In this study, a single MT-SOFC was studied in order to establish the measurement technique and numerical simulation implementation as a prerequisite before further test involving a 7 cell MT-SOFC stack.
feb-2013
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore ING-IND/08 - MACCHINE A FLUIDO
English
Con Impact Factor ISI
Solid Oxide fuel cell; microtubular cells
Lawlor, V., Klein, K., Hochenauer, C., Griesser, S., Kuehn, S., Olabi, A., et al. (2013). Experimental and Numerical Study of Various MT-SOFC Flow Manifold Techniques: Single MT-SOFC Analysis. JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 10(1), 011003 [10.1115/1.4023216].
Lawlor, V; Klein, K; Hochenauer, C; Griesser, S; Kuehn, S; Olabi, A; Cordiner, S; Buchinger, G
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
fc-10-1-011003.pdf

accesso aperto

Dimensione 2.53 MB
Formato Adobe PDF
2.53 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/77596
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 13
social impact