PURPOSE: To assess the efficacy and safety of the Outback device in patients with a chronic total occlusion (CTO) of the superficial femoral artery and evaluate its impact on fluoroscopy and procedural times. MATERIALS AND METHODS: From October 2006 to March 2007, 52 patients affected by TASC II-D superficial femoral artery CTO were treated with subintimal recanalization. Clinical indications for endovascular recanalization were: claudication, tissue loss, and at rest leg pain with critical limb ischemia. In 26 patients the manual reentry technique was used and in 26 the OUTBACK® LTD Re-Entry Catheter was used. Total procedure time, fluoroscopy time and precision in targeting the expected reentry site have been compared. RESULTS: Technical success was achieved in all cases (100%). In group 2, the planned in-target re-entry was achieved in 11/26 cases (42.3%). The procedure was performed with a traditional antegrade approach in 23/26 (88.4%) cases and in three cases (11.6%) a combined antegrade/retrograde approach was necessary. In group 1, the in-target re-entry was achieved in 26/26 cases (100%). In group 2, the mean procedural time was 55.4 ± 14.2 min with a mean fluoroscopy time 39.6 ± 13.9 min compared to 36.0 ± 9.4 min and 29.8 ± 8.9 min, respectively, of group 1 (P < 0.0001). CONCLUSIONS: In our experience, the use of this device is very useful for the revascularization of chronic femoral occlusions, even calcific, in which an accurate re-entry cannot be achieved with the conventional subintimal technique. In these cases, the Outback device grants high technical success rates and a significant reduction of procedural and fluoroscopy times.

Gandini, R., Fabiano, S., Spano, S., Volpi, T., Morosetti, D., Chiaravalloti, A., et al. (2012). Randomized control study of the outback LTD reentry catheter versus manual reentry for the treatment of chronic total occlusions in the superficial femoral artery. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS(11) [10.1002/ccd.24742].

Randomized control study of the outback LTD reentry catheter versus manual reentry for the treatment of chronic total occlusions in the superficial femoral artery.

GANDINI, ROBERTO;SIMONETTI, GIOVANNI MARIA EGISTO
2012-01-01

Abstract

PURPOSE: To assess the efficacy and safety of the Outback device in patients with a chronic total occlusion (CTO) of the superficial femoral artery and evaluate its impact on fluoroscopy and procedural times. MATERIALS AND METHODS: From October 2006 to March 2007, 52 patients affected by TASC II-D superficial femoral artery CTO were treated with subintimal recanalization. Clinical indications for endovascular recanalization were: claudication, tissue loss, and at rest leg pain with critical limb ischemia. In 26 patients the manual reentry technique was used and in 26 the OUTBACK® LTD Re-Entry Catheter was used. Total procedure time, fluoroscopy time and precision in targeting the expected reentry site have been compared. RESULTS: Technical success was achieved in all cases (100%). In group 2, the planned in-target re-entry was achieved in 11/26 cases (42.3%). The procedure was performed with a traditional antegrade approach in 23/26 (88.4%) cases and in three cases (11.6%) a combined antegrade/retrograde approach was necessary. In group 1, the in-target re-entry was achieved in 26/26 cases (100%). In group 2, the mean procedural time was 55.4 ± 14.2 min with a mean fluoroscopy time 39.6 ± 13.9 min compared to 36.0 ± 9.4 min and 29.8 ± 8.9 min, respectively, of group 1 (P < 0.0001). CONCLUSIONS: In our experience, the use of this device is very useful for the revascularization of chronic femoral occlusions, even calcific, in which an accurate re-entry cannot be achieved with the conventional subintimal technique. In these cases, the Outback device grants high technical success rates and a significant reduction of procedural and fluoroscopy times.
2012
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/36 - DIAGNOSTICA PER IMMAGINI E RADIOTERAPIA
English
Con Impact Factor ISI
Gandini, R., Fabiano, S., Spano, S., Volpi, T., Morosetti, D., Chiaravalloti, A., et al. (2012). Randomized control study of the outback LTD reentry catheter versus manual reentry for the treatment of chronic total occlusions in the superficial femoral artery. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS(11) [10.1002/ccd.24742].
Gandini, R; Fabiano, S; Spano, S; Volpi, T; Morosetti, D; Chiaravalloti, A; Nano, G; Simonetti, Gme
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/74289
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 37
social impact