In this paper we propose the construction and application of a portable multi-purpose biosensor array for the simultaneous detection of a wide range of endocrine disruptor chemicals (EDCs), based on the recognition operated by various enzymes and microorganisms. The developed biosensor combines both electrochemical and optical transduction systems, in order to increase the number of chemical species which can be monitored. Considering to the maximum residue level (MRL) of contaminants established by the European Commission, the biosensor system was able to detect most of the chemicals analysed with very high sensitivity. In particular, atrazine and diuron were detected with a limit of detection of 0.5 nM, with an RSD% less than 5%; paraoxon and chlorpyrifos were revealed with a detection of 5 mu M and 4.5 mu M, respectively, with an RSD% less than 6%; catechol and bisphenol A were identified with a limit of detection of 1 mu M and 35 mu M respectively, with an RSD% less than 5%.

Scognamiglio, V., Pezzotti, I., Pezzotti, G., Cano, J., Manfredonia, I., Katia Buonasera, K., et al. (2012). Towards an integrated biosensor array for simultaneous and rapid multi-analysis of endocrine disrupting chemicals. ANALYTICA CHIMICA ACTA, 751, 161-170 [10.1016/j.aca.2012.09.010].

Towards an integrated biosensor array for simultaneous and rapid multi-analysis of endocrine disrupting chemicals

ARDUINI, FABIANA;MOSCONE DINIA, DANILA;PALLESCHI, GIUSEPPE;
2012-01-01

Abstract

In this paper we propose the construction and application of a portable multi-purpose biosensor array for the simultaneous detection of a wide range of endocrine disruptor chemicals (EDCs), based on the recognition operated by various enzymes and microorganisms. The developed biosensor combines both electrochemical and optical transduction systems, in order to increase the number of chemical species which can be monitored. Considering to the maximum residue level (MRL) of contaminants established by the European Commission, the biosensor system was able to detect most of the chemicals analysed with very high sensitivity. In particular, atrazine and diuron were detected with a limit of detection of 0.5 nM, with an RSD% less than 5%; paraoxon and chlorpyrifos were revealed with a detection of 5 mu M and 4.5 mu M, respectively, with an RSD% less than 6%; catechol and bisphenol A were identified with a limit of detection of 1 mu M and 35 mu M respectively, with an RSD% less than 5%.
2012
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/01 - CHIMICA ANALITICA
English
Con Impact Factor ISI
SCREEN-PRINTED ELECTRODE; PESTICIDES; HERBICIDES; ATRAZINE
Scognamiglio, V., Pezzotti, I., Pezzotti, G., Cano, J., Manfredonia, I., Katia Buonasera, K., et al. (2012). Towards an integrated biosensor array for simultaneous and rapid multi-analysis of endocrine disrupting chemicals. ANALYTICA CHIMICA ACTA, 751, 161-170 [10.1016/j.aca.2012.09.010].
Scognamiglio, V; Pezzotti, I; Pezzotti, G; Cano, J; Manfredonia, I; Katia Buonasera, K; Arduini, F; MOSCONE DINIA, D; Palleschi, G; Giardi, M
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/73448
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 27
social impact