A tunnel diode non-linear transmission line has been investigated for second and third harmonic generation purposes. Design criteria are given and performance predictions have been obtained simulating the single diode behavior by means of a polynomial expression. An optimization of the non-linear transmission line as a harmonic generator has been obtained as a function of the number of diodes, their separation distances and the bias voltage.
Bartolucci, G., Dragoman, M., Marcelli, R., Pini, F. (1995). Design considerations for tunnel diode non-linear transmission lines. INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 16(10), 1719-1732 [10.1007/BF02068684].
Design considerations for tunnel diode non-linear transmission lines
BARTOLUCCI, GIANCARLO;
1995-01-01
Abstract
A tunnel diode non-linear transmission line has been investigated for second and third harmonic generation purposes. Design criteria are given and performance predictions have been obtained simulating the single diode behavior by means of a polynomial expression. An optimization of the non-linear transmission line as a harmonic generator has been obtained as a function of the number of diodes, their separation distances and the bias voltage.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.