Purpose: The aim of this study was to investigate whether an electrical device for dental adhesive application (ElectroBond) influences bonding of two-step etch-and-rinse adhesives. Materials and Methods: Human teeth were selected and cut perpendicularly to their long axis to expose middle/deep dentin. Specimens were then longitudinally sectioned into halves (experimental and control halves) to create two similar bonding substrates. Experimental halves were bonded using an ElectroBond-assisted application, while control halves were bonded with disposable sponges. The adhesives tested were Adper Scotchbond 1XT and XP-BOND. Bonded specimens were submitted to the microtensile bond strength test. Additional adhesive interfaces were prepared and processed for nanoleakage investigation involving TEM examination. Results: The microtensile bond test revealed higher values (p < 0.05) for both adhesives if ElectroBond was used during layering (55.5 +/- 7.9 IVIPa for Adper Scotchbond 1XT and 54.7 +/- 7.1 IVIPa for XP-BOND) compared to the conventional mechanical adhesive application technique (41.1 +/- 6.1 MPa for Adper Scotchbond 1XT and 38.0 +/- 7.8 MPa for XP-BOND). No difference between the two adhesives was found under the same application conditions. With electricity-assisted application, TEM micrographs revealed a significant decrease in nanoleakage expression compared to the controls. Conclusion: The use of an electric current produced by ElectroBond during the application of two-step etch-and-rinse adhesives may enhance resin impregnation, thus improving dentin hybridization. Further studies should be done to confirm that this device can similarly improve adhesive application in vivo.

Mazzoni, A., Visintini, E., Vita, F., Pasquantonio, G., Saboia, V., Ruggeri, A., et al. (2009). ElectroBond Improves Immediate Dentin Microtensile Bond Strength of Two Etch-and-Rinse Adhesives. JOURNAL OF ADHESIVE DENTISTRY, 11(1), 27-33.

ElectroBond Improves Immediate Dentin Microtensile Bond Strength of Two Etch-and-Rinse Adhesives

PASQUANTONIO, GUIDO;
2009-01-01

Abstract

Purpose: The aim of this study was to investigate whether an electrical device for dental adhesive application (ElectroBond) influences bonding of two-step etch-and-rinse adhesives. Materials and Methods: Human teeth were selected and cut perpendicularly to their long axis to expose middle/deep dentin. Specimens were then longitudinally sectioned into halves (experimental and control halves) to create two similar bonding substrates. Experimental halves were bonded using an ElectroBond-assisted application, while control halves were bonded with disposable sponges. The adhesives tested were Adper Scotchbond 1XT and XP-BOND. Bonded specimens were submitted to the microtensile bond strength test. Additional adhesive interfaces were prepared and processed for nanoleakage investigation involving TEM examination. Results: The microtensile bond test revealed higher values (p < 0.05) for both adhesives if ElectroBond was used during layering (55.5 +/- 7.9 IVIPa for Adper Scotchbond 1XT and 54.7 +/- 7.1 IVIPa for XP-BOND) compared to the conventional mechanical adhesive application technique (41.1 +/- 6.1 MPa for Adper Scotchbond 1XT and 38.0 +/- 7.8 MPa for XP-BOND). No difference between the two adhesives was found under the same application conditions. With electricity-assisted application, TEM micrographs revealed a significant decrease in nanoleakage expression compared to the controls. Conclusion: The use of an electric current produced by ElectroBond during the application of two-step etch-and-rinse adhesives may enhance resin impregnation, thus improving dentin hybridization. Further studies should be done to confirm that this device can similarly improve adhesive application in vivo.
2009
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE
English
Con Impact Factor ISI
dentin bonding systems; electric current; TEM; microtensile; dentin
SINGLE-STEP ADHESIVES; HYBRID LAYER; COMPARATIVE SEM; IN-VITRO; NANOLEAKAGE; TOOTH; IONTOPHORESIS; PERMEABILITY; CONVERSION; INTERFACE
7
Mazzoni, A., Visintini, E., Vita, F., Pasquantonio, G., Saboia, V., Ruggeri, A., et al. (2009). ElectroBond Improves Immediate Dentin Microtensile Bond Strength of Two Etch-and-Rinse Adhesives. JOURNAL OF ADHESIVE DENTISTRY, 11(1), 27-33.
Mazzoni, A; Visintini, E; Vita, F; Pasquantonio, G; Saboia, V; Ruggeri, A; Di Lenarda, R; Dorigo, E; Breschi, L
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
The_journal_of_adhesive_2009.pdf

solo utenti autorizzati

Licenza: Copyright dell'editore
Dimensione 130.85 kB
Formato Adobe PDF
130.85 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/59117
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 14
social impact