In an effort to determine the factors influencing the abnormal ventricular filling patterns of fetuses of type I diabetic mothers, Doppler flow velocity waveforms were recorded from fetal atrioventricular valves in 37 pregnancies complicated by type I diabetes immediately before an elective cesarean section. The ratio between the peak velocities during early passive ventricular filling and active atrial filling was calculated at the level of both atrioventricular valves and related to different factors including ventricular chamber wall thickness, heart rate, umbilical vein hematocrit and time to peak velocities values obtained at the outflow tract. Multiple stepwise regression demonstrated that the interventricular wall thickness, heart rate and hematocrit values significantly and independently affected the ratios between early and active ventricular filling from mitral and tricuspid valves. As a consequence all these factors should be taken into account in the interpretation of atrioventricular Doppler indices.

Rizzo, G., Pietropolli, A., Capponi, A., Cacciatore, C., Arduini, D., Romanini, C. (1994). ANALYSIS OF FACTORS INFLUENCING VENTRICULAR FILLING PATTERNS IN FETUSES OF TYPE-I DIABETIC MOTHERS. JOURNAL OF PERINATAL MEDICINE, 22(2), 149-157.

ANALYSIS OF FACTORS INFLUENCING VENTRICULAR FILLING PATTERNS IN FETUSES OF TYPE-I DIABETIC MOTHERS

RIZZO, GIUSEPPE;PIETROPOLLI, A;ARDUINI, DOMENICO;
1994-01-01

Abstract

In an effort to determine the factors influencing the abnormal ventricular filling patterns of fetuses of type I diabetic mothers, Doppler flow velocity waveforms were recorded from fetal atrioventricular valves in 37 pregnancies complicated by type I diabetes immediately before an elective cesarean section. The ratio between the peak velocities during early passive ventricular filling and active atrial filling was calculated at the level of both atrioventricular valves and related to different factors including ventricular chamber wall thickness, heart rate, umbilical vein hematocrit and time to peak velocities values obtained at the outflow tract. Multiple stepwise regression demonstrated that the interventricular wall thickness, heart rate and hematocrit values significantly and independently affected the ratios between early and active ventricular filling from mitral and tricuspid valves. As a consequence all these factors should be taken into account in the interpretation of atrioventricular Doppler indices.
1994
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/40 - GINECOLOGIA E OSTETRICIA
English
Con Impact Factor ISI
COLOR DOPPLER; DIASTOLIC FUNCTION; ECHOCARDIOGRAPHY; FETAL HEART; FETAL HEMATOCRIT; TYPE-I DIABETES
9
Rizzo, G., Pietropolli, A., Capponi, A., Cacciatore, C., Arduini, D., Romanini, C. (1994). ANALYSIS OF FACTORS INFLUENCING VENTRICULAR FILLING PATTERNS IN FETUSES OF TYPE-I DIABETIC MOTHERS. JOURNAL OF PERINATAL MEDICINE, 22(2), 149-157.
Rizzo, G; Pietropolli, A; Capponi, A; Cacciatore, C; Arduini, D; Romanini, C
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/54392
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 16
social impact