The in vivo evaluation of prosthetic device performance is often difficult, if not impossible. In particular, in order to deal with potential problems such as thrombosis, haemolysis, etc., which could arise when a patient undergoes heart valve replacement, a thorough understanding of the blood flow dynamics inside the devices interacting with natural or composite tissues is required. Numerical simulation, combining both computational fluid and structure dynamics, could provide detailed information on such complex problems. In this work, a numerical investigation of the mechanics of two composite aortic prostheses during a cardiac cycle is presented. The numerical tool presented is able to reproduce accurately the flow and structure dynamics of the prostheses. The analysis shows that the vortical structures forming inside the two different grafts do not influence the kinematics of a bileaflet valve or the main coronary flow, whereas major differences are present for the stress status near the suture line of the coronaries to the prostheses. The results are in agreement with in vitro and in vivo observations found in literature.

De, T., M. D., P., Welterlt, L., DE PAULIS, R., Verzicco, R. (2011). Evaluation of prosthetic-valved devices by means of numerical simulations. PHILOSOPHICAL TRANSACTIONS - ROYAL SOCIETY. MATHEMATICAL, PHYSICAL AND ENGINEERING SCIENCES, 369, 2502-2509 [10.1098/rsta.2010.0365].

Evaluation of prosthetic-valved devices by means of numerical simulations

DE PAULIS, RUGGERO;VERZICCO, ROBERTO
2011-01-01

Abstract

The in vivo evaluation of prosthetic device performance is often difficult, if not impossible. In particular, in order to deal with potential problems such as thrombosis, haemolysis, etc., which could arise when a patient undergoes heart valve replacement, a thorough understanding of the blood flow dynamics inside the devices interacting with natural or composite tissues is required. Numerical simulation, combining both computational fluid and structure dynamics, could provide detailed information on such complex problems. In this work, a numerical investigation of the mechanics of two composite aortic prostheses during a cardiac cycle is presented. The numerical tool presented is able to reproduce accurately the flow and structure dynamics of the prostheses. The analysis shows that the vortical structures forming inside the two different grafts do not influence the kinematics of a bileaflet valve or the main coronary flow, whereas major differences are present for the stress status near the suture line of the coronaries to the prostheses. The results are in agreement with in vitro and in vivo observations found in literature.
2011
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore ING-IND/06 - FLUIDODINAMICA
English
Con Impact Factor ISI
Prosthetic aortic valve, biofluid mechanics
De, T., M. D., P., Welterlt, L., DE PAULIS, R., Verzicco, R. (2011). Evaluation of prosthetic-valved devices by means of numerical simulations. PHILOSOPHICAL TRANSACTIONS - ROYAL SOCIETY. MATHEMATICAL, PHYSICAL AND ENGINEERING SCIENCES, 369, 2502-2509 [10.1098/rsta.2010.0365].
De, T; M. D., P; Welterlt, L; DE PAULIS, R; Verzicco, R
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/52705
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact