The long-term reproducibility of responses is one of the most demanded qualities of chemical sensors. Among the several phenomena affecting the reproducibility those related to imperfect experimental design are sometimes dominant. In this work an experimental design centered on a pattern of short-time repeated exposures (STE) to gases is presented as a method to increase the reproducibility of sensors responses. The method was validated in a experiment where an array of metalloporphyrins coated quartz microbalances is used to classify two volatile compounds and their mixture. The experiment was designed in order to compare the performance of the proposed method with that achieved with the standard long-time gas exposures. The STE results show an improvement of the reproducibility of the sensorial system respect to the standard protocol providing a complete identification after 45 days from the training procedure. The results also evidence the fundamental role of the first exposure to improve the reproducibility of the other pulses responses composing STE pattern. © 2011 Elsevier B.V. All rights reserved.

Martinelli, E., Santonico, M., Pennazza, G., Paolesse, R., D'Amico, A., DI NATALE, C. (2011). Short time gas delivery pattern improves long-term sensor reproducibility. SENSORS AND ACTUATORS. B, CHEMICAL, 156(2), 753-759 [10.1016/j.snb.2011.02.034].

Short time gas delivery pattern improves long-term sensor reproducibility

MARTINELLI, EUGENIO;PAOLESSE, ROBERTO;D'AMICO, ARNALDO;DI NATALE, CORRADO
2011-01-01

Abstract

The long-term reproducibility of responses is one of the most demanded qualities of chemical sensors. Among the several phenomena affecting the reproducibility those related to imperfect experimental design are sometimes dominant. In this work an experimental design centered on a pattern of short-time repeated exposures (STE) to gases is presented as a method to increase the reproducibility of sensors responses. The method was validated in a experiment where an array of metalloporphyrins coated quartz microbalances is used to classify two volatile compounds and their mixture. The experiment was designed in order to compare the performance of the proposed method with that achieved with the standard long-time gas exposures. The STE results show an improvement of the reproducibility of the sensorial system respect to the standard protocol providing a complete identification after 45 days from the training procedure. The results also evidence the fundamental role of the first exposure to improve the reproducibility of the other pulses responses composing STE pattern. © 2011 Elsevier B.V. All rights reserved.
2011
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore ING-INF/01 - ELETTRONICA
Settore CHIM/07 - FONDAMENTI CHIMICI DELLE TECNOLOGIE
English
Con Impact Factor ISI
Martinelli, E., Santonico, M., Pennazza, G., Paolesse, R., D'Amico, A., DI NATALE, C. (2011). Short time gas delivery pattern improves long-term sensor reproducibility. SENSORS AND ACTUATORS. B, CHEMICAL, 156(2), 753-759 [10.1016/j.snb.2011.02.034].
Martinelli, E; Santonico, M; Pennazza, G; Paolesse, R; D'Amico, A; DI NATALE, C
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/52230
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 22
social impact