We wanted to determine whether liver contrast-enhanced ultrasound (CEUS)–derived peak signal intensity (PSI) and peak signal intensity/time (PIT) predict liver fibrosis in chronic hepatitis C (CHC). Fortynine patients with CHC (METAVIR classification) and 10 control subjects were included in the study. After a bolus of 2.4 mL SonoVue (Bracco Imaging, Milan, Italy) solution was injected into a peripheral vein, the right lobe of the liver containing the right portal vein was scanned in a transverse section. Two-dimensional sonography was performed using the Philips iU22 ultrasound system (Philips Healthcare, Best, the Netherlands). A 1.0–5.0-MHz (C5-1) wideband convex transducer was used, applying the following settings in all cases. Regions of interest were manually drawn over the right liver lobe and over the portal vein (PV). Liver parenchyma PSI (LPpsi) and PIT (LPpit), portal vein PSI (PVpsi) and PIT (PVpit) were automatically calculated. dPSI was defined as the difference between PVpsi and LPpsi. A significant correlation was observed between PAPSI and fibrosis scores. When patients were stratified according to their LPpsi, a significant difference was achieved only between patients with fibrosis score 0–1 vs. 2–3 and 2 vs. 4. Statistically significant differences between all fibrosis scores, except 0 vs. 1 and 3 vs. 4 were observed when dPSI was used to stratify patients. Overall diagnostic accuracy of LPpsi and dPSI measurement for severe fibrosis by area under the receiving operator characteristic curve analysis was, respectively, 0.87 and 0.88.We suggest that liver CEUS perfusion could have the potential to be used as a complementary tool for the evaluation of liver fibrosis. However, further large-scale studies are required to accurately assess its accuracy in the evaluation of liver fibrosis.

Orlacchio, A., Bolacchi, F., Petrella, M., Pastorelli, D., Bazzocchi, G., Angelico, M., et al. (2011). Liver contrast enhanced ultrasound perfusion imaging in the evaluation of chronic hepatitis C fibrosis: preliminary results. ULTRASOUND IN MEDICINE AND BIOLOGY, 37, 1-6 [10.1016/j.ultrasmedbio.2010.10.012].

Liver contrast enhanced ultrasound perfusion imaging in the evaluation of chronic hepatitis C fibrosis: preliminary results

ORLACCHIO, ANTONIO;ANGELICO, MARIO;SIMONETTI, GIOVANNI MARIA EGISTO
2011-01-01

Abstract

We wanted to determine whether liver contrast-enhanced ultrasound (CEUS)–derived peak signal intensity (PSI) and peak signal intensity/time (PIT) predict liver fibrosis in chronic hepatitis C (CHC). Fortynine patients with CHC (METAVIR classification) and 10 control subjects were included in the study. After a bolus of 2.4 mL SonoVue (Bracco Imaging, Milan, Italy) solution was injected into a peripheral vein, the right lobe of the liver containing the right portal vein was scanned in a transverse section. Two-dimensional sonography was performed using the Philips iU22 ultrasound system (Philips Healthcare, Best, the Netherlands). A 1.0–5.0-MHz (C5-1) wideband convex transducer was used, applying the following settings in all cases. Regions of interest were manually drawn over the right liver lobe and over the portal vein (PV). Liver parenchyma PSI (LPpsi) and PIT (LPpit), portal vein PSI (PVpsi) and PIT (PVpit) were automatically calculated. dPSI was defined as the difference between PVpsi and LPpsi. A significant correlation was observed between PAPSI and fibrosis scores. When patients were stratified according to their LPpsi, a significant difference was achieved only between patients with fibrosis score 0–1 vs. 2–3 and 2 vs. 4. Statistically significant differences between all fibrosis scores, except 0 vs. 1 and 3 vs. 4 were observed when dPSI was used to stratify patients. Overall diagnostic accuracy of LPpsi and dPSI measurement for severe fibrosis by area under the receiving operator characteristic curve analysis was, respectively, 0.87 and 0.88.We suggest that liver CEUS perfusion could have the potential to be used as a complementary tool for the evaluation of liver fibrosis. However, further large-scale studies are required to accurately assess its accuracy in the evaluation of liver fibrosis.
2011
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/36 - DIAGNOSTICA PER IMMAGINI E RADIOTERAPIA
English
Con Impact Factor ISI
Liver fibrosis, Perfusion imaging, Contrast-enhanced ultrasound, Chronic hepatitis C
Orlacchio, A., Bolacchi, F., Petrella, M., Pastorelli, D., Bazzocchi, G., Angelico, M., et al. (2011). Liver contrast enhanced ultrasound perfusion imaging in the evaluation of chronic hepatitis C fibrosis: preliminary results. ULTRASOUND IN MEDICINE AND BIOLOGY, 37, 1-6 [10.1016/j.ultrasmedbio.2010.10.012].
Orlacchio, A; Bolacchi, F; Petrella, M; Pastorelli, D; Bazzocchi, G; Angelico, M; Simonetti, Gme
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Orlacchio_UMB.pdf

accesso aperto

Dimensione 762.78 kB
Formato Adobe PDF
762.78 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/51910
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 34
social impact