Accurate determination of hepatitis C virus RNA level is essential for evaluating the response to antiviral therapy, to determine the duration of treatment, and to predict treatment outcome. Currently, two real-time based polymerase chain reaction assays are used widely to monitor the hepatitis C RNA level: the Abbott RealTime HCV assay and the Cobas Taqman HCV assay. Recently, a third assay has become commercially available: the Artus HCV QS-RGQ assay, which uses the QIAsymphony SP/AS platform for sample preparation and PCR-setup, and the Rotor-Gene Q for amplification and detection. In this study, the performance of the Artus HCV QS-RGQ assay was tested on 105 plasma samples and compared to that of the Cobas Taqman HCV assay. Linear regression analysis showed a good agreement between the two assays. A slightly better sensitivity was observed with the Cobas Taqman assay, while higher hepatitis C viral RNA levels were measured by the Artus HCV QS-RGQ assay in samples positive for hepatitis C genotypes 4. Taken together, the data suggest that the Artus HCV QS-RGQ assay is useful in a diagnostic setting. The combination with the versatile QIAsymphony SP/AS system may represent a major advantage for clinical virological laboratories aiming at optimizing their workflow.

Paba, P., Fabeni, L., Perno, C.f., Ciotti, M. (2011). Performance evaluation of the Artus hepatitis C virus QS-RGQ assay. JOURNAL OF VIROLOGICAL METHODS [10.1016/j.jviromet.2011.09.024].

Performance evaluation of the Artus hepatitis C virus QS-RGQ assay

PERNO, CARLO FEDERICO;
2011-10-05

Abstract

Accurate determination of hepatitis C virus RNA level is essential for evaluating the response to antiviral therapy, to determine the duration of treatment, and to predict treatment outcome. Currently, two real-time based polymerase chain reaction assays are used widely to monitor the hepatitis C RNA level: the Abbott RealTime HCV assay and the Cobas Taqman HCV assay. Recently, a third assay has become commercially available: the Artus HCV QS-RGQ assay, which uses the QIAsymphony SP/AS platform for sample preparation and PCR-setup, and the Rotor-Gene Q for amplification and detection. In this study, the performance of the Artus HCV QS-RGQ assay was tested on 105 plasma samples and compared to that of the Cobas Taqman HCV assay. Linear regression analysis showed a good agreement between the two assays. A slightly better sensitivity was observed with the Cobas Taqman assay, while higher hepatitis C viral RNA levels were measured by the Artus HCV QS-RGQ assay in samples positive for hepatitis C genotypes 4. Taken together, the data suggest that the Artus HCV QS-RGQ assay is useful in a diagnostic setting. The combination with the versatile QIAsymphony SP/AS system may represent a major advantage for clinical virological laboratories aiming at optimizing their workflow.
5-ott-2011
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/07 - MICROBIOLOGIA E MICROBIOLOGIA CLINICA
English
Con Impact Factor ISI
Paba, P., Fabeni, L., Perno, C.f., Ciotti, M. (2011). Performance evaluation of the Artus hepatitis C virus QS-RGQ assay. JOURNAL OF VIROLOGICAL METHODS [10.1016/j.jviromet.2011.09.024].
Paba, P; Fabeni, L; Perno, Cf; Ciotti, M
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

Questo articolo è pubblicato sotto una Licenza Licenza Creative Commons Creative Commons

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/51791
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact