Background: A variety of human tumours, including non-small cell lung cancer, overexpress epithelial growth factor (EGF) receptors. In this study we evaluated the feasibility of immunoscintigraphy with a technetium-99m-labelled monoclonal antibody directed towards the EGF receptor (MINT5). Materials and Methods: The labelling with technetium-99m was performed using the glucoheptonate-iminothiolane method. Eight patients with non-small cell lung cancer were i.v. injected 740 MBq of MINT5. Neither side-effects, nor toxicity, nor HAMA response were observed. Each patient was submitted to total body planar images in anterior and posterior projections at 1-2 hours and at 4-6 hours after the injection. Results: Uptake of MINT5 was mainly visible in liver, spleen and bone marrow; it proved stable in vivo. The primary lung cancer was imaged in 7 out of 8 patients and metastases were detected in 3 out of 3 cases. Conclusion:. MINT5 is a safe and promising radiopharmaceutical for in vivo localization and biological characterization of non-small cell lung cancer.
Schillaci, O., Danieli, R., Picardi, V., Bagni, O., Di Loreto, M., Scopinaro, F. (2001). Immunoscintigraphy with a technetium-99m labelled anti-epithelial growth factor receptor antibody in patients with non-small cell lung cancer. ANTICANCER RESEARCH, 21(5), 3571-3574.
Immunoscintigraphy with a technetium-99m labelled anti-epithelial growth factor receptor antibody in patients with non-small cell lung cancer
Schillaci, O;Danieli, R;
2001-01-01
Abstract
Background: A variety of human tumours, including non-small cell lung cancer, overexpress epithelial growth factor (EGF) receptors. In this study we evaluated the feasibility of immunoscintigraphy with a technetium-99m-labelled monoclonal antibody directed towards the EGF receptor (MINT5). Materials and Methods: The labelling with technetium-99m was performed using the glucoheptonate-iminothiolane method. Eight patients with non-small cell lung cancer were i.v. injected 740 MBq of MINT5. Neither side-effects, nor toxicity, nor HAMA response were observed. Each patient was submitted to total body planar images in anterior and posterior projections at 1-2 hours and at 4-6 hours after the injection. Results: Uptake of MINT5 was mainly visible in liver, spleen and bone marrow; it proved stable in vivo. The primary lung cancer was imaged in 7 out of 8 patients and metastases were detected in 3 out of 3 cases. Conclusion:. MINT5 is a safe and promising radiopharmaceutical for in vivo localization and biological characterization of non-small cell lung cancer.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.