Polycrystalline chemical vapour deposited (CVD) diamond film is an interesting material for neutron detection and dosimetry. However, the use of CVD diamond detectors is still limited by the low-level signal pulse produced because of the high energy required to produce an electron–hole pair in diamond (13.2 eV) and by the reduced charge collection efficiency owing to several types of traps for electrons and holes in CVD films. A new type of CVD diamond detector with high gain (HG) contacts was produced as part of the collaboration between the ENEA Fusion Division and the Faculty of Engineering of Rome ‘Tor Vergata’ University. In this paper the performance of the HG CVD diamond detector is presented and possible applications of CVD diamond detectors to neutron dosimetry are also discussed.

Angelone, M., Marinelli, M., Milani, E., Tucciarone, A., Pillon, M., Pucella, G., et al. (2006). Neutron detection and dosimetry using polycrystalline CVD diamond detectors with high collection efficiency. RADIATION PROTECTION DOSIMETRY, 120(1-4), 345-348 [10.1093/rpd/nci634].

Neutron detection and dosimetry using polycrystalline CVD diamond detectors with high collection efficiency

MARINELLI, MARCO;MILANI, ENRICO;TUCCIARONE, ALDO;VERONA RINATI, GIANLUCA
2006-01-01

Abstract

Polycrystalline chemical vapour deposited (CVD) diamond film is an interesting material for neutron detection and dosimetry. However, the use of CVD diamond detectors is still limited by the low-level signal pulse produced because of the high energy required to produce an electron–hole pair in diamond (13.2 eV) and by the reduced charge collection efficiency owing to several types of traps for electrons and holes in CVD films. A new type of CVD diamond detector with high gain (HG) contacts was produced as part of the collaboration between the ENEA Fusion Division and the Faculty of Engineering of Rome ‘Tor Vergata’ University. In this paper the performance of the HG CVD diamond detector is presented and possible applications of CVD diamond detectors to neutron dosimetry are also discussed.
2006
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore FIS/01 - FISICA SPERIMENTALE
English
Con Impact Factor ISI
Angelone, M., Marinelli, M., Milani, E., Tucciarone, A., Pillon, M., Pucella, G., et al. (2006). Neutron detection and dosimetry using polycrystalline CVD diamond detectors with high collection efficiency. RADIATION PROTECTION DOSIMETRY, 120(1-4), 345-348 [10.1093/rpd/nci634].
Angelone, M; Marinelli, M; Milani, E; Tucciarone, A; Pillon, M; Pucella, G; VERONA RINATI, G
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/51671
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 4
social impact