The validation of a new dynamometer for evaluation of dynamic muscle work is presented. The device was based on a precise measurement of load displacements of any machine using gravitational loads as external resistance. It allowed, through a sensor consisting of an infrared photo interrupter, the calculation of velocity, force and power during concentric, eccentric and stretch-shortening cycle activity. To validate the dynamometer 33 male and female track and field athletes (12 throwers and 21 jumpers) participated in the study. The throwers (4 women and 8 men) were asked to perform half-squat exercises on a slide machine with a load of 100% of the subject's body mass. The day-to-day reproducibility of half-squat exercises gave a correlation coefficient of r = 0.88, 0.97 and 0.95 for average push-off force (AF), average push-off velocity (AV), and average push-off power (AP) respectively. Comparison of half-squat measurements was performed against jumping and running test evaluation by the jumpers (7 women and 14 men). The interrelationships among the different variables studied demonstrated a strong correlation between AF, AV and AP and sprinting and jumping parameters (r = 0.53-0.97; P < 0.05-0.001). Using values of AF, AV and AP developed in half-squat exercises executed with different loads, ranging from 35% to 210% of the subject's body mass, it was also possible to establish the force-velocity and power-velocity relationships for both male and female jumpers. In any individual case, the maximal error due to the measurement system was calculated to be less than 0.3%, 0.9% and 1.2% for AF, AV, and AP respectively. Given the accuracy of the ergometer, the high reliability found between 2 days of measurements, and the specificity of the results it is suggested that the dynamic dynamometer would be suitable for evaluation of athletes performing specific skills. In addition, because single and multiple joint movements involving appropriate muscle groups call be easily performed, physiological characteristics could be evaluated for both athletic and rehabilitation purposes. Therefore, because of its simplicity of use and application, and its low cost the dynamometer would be suitable for both laboratory and field conditions.

Bosco, C., Belli, A., Astrua, M., Tihanyi, J., Pozzo, R., Kellis, S., et al. (1995). A DYNAMOMETER FOR EVALUATION OF DYNAMIC MUSCLE WORK. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 70(5), 379-386.

A DYNAMOMETER FOR EVALUATION OF DYNAMIC MUSCLE WORK

FOTI, CALOGERO;
1995-01-01

Abstract

The validation of a new dynamometer for evaluation of dynamic muscle work is presented. The device was based on a precise measurement of load displacements of any machine using gravitational loads as external resistance. It allowed, through a sensor consisting of an infrared photo interrupter, the calculation of velocity, force and power during concentric, eccentric and stretch-shortening cycle activity. To validate the dynamometer 33 male and female track and field athletes (12 throwers and 21 jumpers) participated in the study. The throwers (4 women and 8 men) were asked to perform half-squat exercises on a slide machine with a load of 100% of the subject's body mass. The day-to-day reproducibility of half-squat exercises gave a correlation coefficient of r = 0.88, 0.97 and 0.95 for average push-off force (AF), average push-off velocity (AV), and average push-off power (AP) respectively. Comparison of half-squat measurements was performed against jumping and running test evaluation by the jumpers (7 women and 14 men). The interrelationships among the different variables studied demonstrated a strong correlation between AF, AV and AP and sprinting and jumping parameters (r = 0.53-0.97; P < 0.05-0.001). Using values of AF, AV and AP developed in half-squat exercises executed with different loads, ranging from 35% to 210% of the subject's body mass, it was also possible to establish the force-velocity and power-velocity relationships for both male and female jumpers. In any individual case, the maximal error due to the measurement system was calculated to be less than 0.3%, 0.9% and 1.2% for AF, AV, and AP respectively. Given the accuracy of the ergometer, the high reliability found between 2 days of measurements, and the specificity of the results it is suggested that the dynamic dynamometer would be suitable for evaluation of athletes performing specific skills. In addition, because single and multiple joint movements involving appropriate muscle groups call be easily performed, physiological characteristics could be evaluated for both athletic and rehabilitation purposes. Therefore, because of its simplicity of use and application, and its low cost the dynamometer would be suitable for both laboratory and field conditions.
1995
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/34 - MEDICINA FISICA E RIABILITATIVA
English
DYNAMIC DYNAMOMETER; GRAVITATIONAL LOADS; FORCE-VELOCITY RELATIONSHIP; MUSCLE POWER; MUSCLE SEX DIFFERENCE
8
Bosco, C., Belli, A., Astrua, M., Tihanyi, J., Pozzo, R., Kellis, S., et al. (1995). A DYNAMOMETER FOR EVALUATION OF DYNAMIC MUSCLE WORK. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 70(5), 379-386.
Bosco, C; Belli, A; Astrua, M; Tihanyi, J; Pozzo, R; Kellis, S; Tsarpela, O; Foti, C; Manno, R; Tranquilli, C
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/51119
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 186
  • ???jsp.display-item.citation.isi??? 161
social impact