For the first time in the literature, radiographs of breast phantoms were obtained using several monochromatic synchrotron radiation x-ray beams of selected energy in the range from 14 to 26 keV. In addition, after optimization of the photon energy as a function of the phantom thickness, several mammographs were obtained on surgically removed human breast specimens containing cancer nodules. Comparison between radiographs using a conventional x-ray unit and those obtained of the same specimens utilizing synchrotron monochromatic beams clearly shows that higher contrast and better resolution can be achieved with synchrotron radiation. These results demonstrate the possibility of obtaining radiographs of excised human breast tissue containing a greater amount of radiological information using synchrotron radiation.

Burattini, E., Gambaccini, M., Marziani, M., Rimondi, O., Indovina, P., Pocek, M., et al. (1992). X-ray mammography with synchrotron radiation. REVIEW OF SCIENTIFIC INSTRUMENTS, 63(1), 638-640 [10.1063/1.1142676].

X-ray mammography with synchrotron radiation

POCEK, MARCO;SIMONETTI, GIOVANNI MARIA EGISTO;
1992-01-01

Abstract

For the first time in the literature, radiographs of breast phantoms were obtained using several monochromatic synchrotron radiation x-ray beams of selected energy in the range from 14 to 26 keV. In addition, after optimization of the photon energy as a function of the phantom thickness, several mammographs were obtained on surgically removed human breast specimens containing cancer nodules. Comparison between radiographs using a conventional x-ray unit and those obtained of the same specimens utilizing synchrotron monochromatic beams clearly shows that higher contrast and better resolution can be achieved with synchrotron radiation. These results demonstrate the possibility of obtaining radiographs of excised human breast tissue containing a greater amount of radiological information using synchrotron radiation.
1992
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/36 - DIAGNOSTICA PER IMMAGINI E RADIOTERAPIA
English
Con Impact Factor ISI
Burattini, E., Gambaccini, M., Marziani, M., Rimondi, O., Indovina, P., Pocek, M., et al. (1992). X-ray mammography with synchrotron radiation. REVIEW OF SCIENTIFIC INSTRUMENTS, 63(1), 638-640 [10.1063/1.1142676].
Burattini, E; Gambaccini, M; Marziani, M; Rimondi, O; Indovina, P; Pocek, M; Simonetti, Gme; Benassi, M; Tirelli, C; Passariello, R
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/49725
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 30
social impact