The possibility to quantify ascorbic acid (AA) using a Ni–Co MOF-coated carbon paper electrode within an extended gate FET setup (EGFET), operated at zero gate potential (open-circuit potential, OCP), has been investigated. Under these conditions, the Ni–Co MOF/CP electrode outperformed the single metal-based Ni-MOF and Co-MOF, demonstrating a wide detection range from 454 nM to 224.9 μM, encompassing both low and high AA levels in human blood, and a response time under 7 seconds. The sensor has shown a pronounced selective response to AA in the presence of several potential interferents such as glucose, sucrose, nicotine, lactose, and fructose. The sensitivity of the Ni–Co MOF/CP sensor to AA was estimated as 6.5284 nA μM−1 cm−2, with a limit of detection (LOD) of 45.1 nM and a limit of quantification (LOQ) of 136 nM. These findings indicate the potential and suitability of the Ni–Co MOF/CP electrode for detecting ascorbic acid in human blood serum. A key novelty of this work is the use of OCP to detect AA with Ni–Co MOF/CP, leveraging proton conduction via a combined Grotthuss and vehicular mechanism.

Prasad Kuppuswamy, G., Vinukumar, A., Pushparaj, K., Murugaiyan, S., Lvova, L., Velappa Jayaraman, S., et al. (2026). Unlocking the potential of proton-mediated detection of ascorbic acid with a Ni–Co bimetallic MOF based extended gate FET. SENSORS & DIAGNOSTICS, 5(5), 705-717 [10.1039/D5SD00217F].

Unlocking the potential of proton-mediated detection of ascorbic acid with a Ni–Co bimetallic MOF based extended gate FET

Kishore Pushparaj;Sujitha Murugaiyan;Larisa Lvova
;
Corrado Di Natale;Yuvaraj Sivalingam
2026-01-01

Abstract

The possibility to quantify ascorbic acid (AA) using a Ni–Co MOF-coated carbon paper electrode within an extended gate FET setup (EGFET), operated at zero gate potential (open-circuit potential, OCP), has been investigated. Under these conditions, the Ni–Co MOF/CP electrode outperformed the single metal-based Ni-MOF and Co-MOF, demonstrating a wide detection range from 454 nM to 224.9 μM, encompassing both low and high AA levels in human blood, and a response time under 7 seconds. The sensor has shown a pronounced selective response to AA in the presence of several potential interferents such as glucose, sucrose, nicotine, lactose, and fructose. The sensitivity of the Ni–Co MOF/CP sensor to AA was estimated as 6.5284 nA μM−1 cm−2, with a limit of detection (LOD) of 45.1 nM and a limit of quantification (LOQ) of 136 nM. These findings indicate the potential and suitability of the Ni–Co MOF/CP electrode for detecting ascorbic acid in human blood serum. A key novelty of this work is the use of OCP to detect AA with Ni–Co MOF/CP, leveraging proton conduction via a combined Grotthuss and vehicular mechanism.
2026
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/07
Settore CHEM-06/A - Fondamenti chimici delle tecnologie
English
Con Impact Factor ISI
Prasad Kuppuswamy, G., Vinukumar, A., Pushparaj, K., Murugaiyan, S., Lvova, L., Velappa Jayaraman, S., et al. (2026). Unlocking the potential of proton-mediated detection of ascorbic acid with a Ni–Co bimetallic MOF based extended gate FET. SENSORS & DIAGNOSTICS, 5(5), 705-717 [10.1039/D5SD00217F].
Prasad Kuppuswamy, G; Vinukumar, A; Pushparaj, K; Murugaiyan, S; Lvova, L; Velappa Jayaraman, S; Di Natale, C; Sivalingam, Y
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Unlocking the potential of proton-mediated detection of ascorbic acid with a Ni–Co bimetallic MOF based extended gate FET_2026.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 2.34 MB
Formato Adobe PDF
2.34 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/474445
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact