After ten years of operation at the LHC, the planar pixel sensors of the innermost barrel layer of the ATLAS Pixel detector have accumulated an average bulk damage fluence in excess of 2×10^15 1 MeV-neutrons equivalent/cm2. The macroscopic effects of this radiation are an increase of the sensor leakage current, a loss of charge collection efficiency and an increase of the depletion voltage. Using regular bias voltage scans performed at the beginning and end of each data taking campaign the evolution of the pixel cluster charge and bulk depletion is studied as a function of particle fluence. Results are interpreted with the modelling provided by standalone TCAD and ATLAS Monte Carlo simulation including radiation damage effects. The dependence of the collected charge and the depletion voltage with integrated luminosity are studied through the full period of operation.

Aad, G., Aakvaag, E., Abbott, B., Abdelhameed, S., Abeling, K., Abicht, N.j., et al. (2026). Study of particle fluence effects on collected charge and depletion voltage of the ATLAS IBL planar pixel sensors. JOURNAL OF INSTRUMENTATION, 21(07) [10.1088/1748-0221/21/07/p07048].

Study of particle fluence effects on collected charge and depletion voltage of the ATLAS IBL planar pixel sensors

Aielli, G.;Camarri, P.;Cerrito, L.;De Sanctis, U.;Di Ciaccio, A.;
2026-01-01

Abstract

After ten years of operation at the LHC, the planar pixel sensors of the innermost barrel layer of the ATLAS Pixel detector have accumulated an average bulk damage fluence in excess of 2×10^15 1 MeV-neutrons equivalent/cm2. The macroscopic effects of this radiation are an increase of the sensor leakage current, a loss of charge collection efficiency and an increase of the depletion voltage. Using regular bias voltage scans performed at the beginning and end of each data taking campaign the evolution of the pixel cluster charge and bulk depletion is studied as a function of particle fluence. Results are interpreted with the modelling provided by standalone TCAD and ATLAS Monte Carlo simulation including radiation damage effects. The dependence of the collected charge and the depletion voltage with integrated luminosity are studied through the full period of operation.
2026
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore PHYS-01/A - Fisica sperimentale delle interazioni fondamentali e applicazioni
English
Con Impact Factor ISI
Particle tracking detectors (Solid-state detectors)
Si microstrip and pad detectors
Solid state detectors
Aad, G., Aakvaag, E., Abbott, B., Abdelhameed, S., Abeling, K., Abicht, N.j., et al. (2026). Study of particle fluence effects on collected charge and depletion voltage of the ATLAS IBL planar pixel sensors. JOURNAL OF INSTRUMENTATION, 21(07) [10.1088/1748-0221/21/07/p07048].
Aad, G; Aakvaag, E; Abbott, B; Abdelhameed, S; Abeling, K; Abicht, Nj; Abidi, Sh; Aboelela, M; Aboulhorma, A; Abramowicz, H; Acharya, Bs; Ackermann, A...espandi
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
jinst.21.2026.P07048.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 2.22 MB
Formato Adobe PDF
2.22 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/474314
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact