The Self-Care of Heart Failure Index (SCHFI) is used widely, but issues with reliability have been evident. Cronbach alpha coefficient is usually used to assess reliability, but this approach assumes a unidimensional scale. The purpose of this article is to address the dimensionality and internal consistency reliability of the SCHFI. This was a secondary analysis of data from 629 adults with heart failure enrolled in three separate studies conducted in the northeastern and northwestern United States. Following testing for scale dimensionality using confirmatory factor analysis, reliability was tested using coefficient alpha and alternative options. Confirmatory factor analysis demonstrated that: (a) the Self-Care Maintenance Scale has a multidimensional four-factor structure; (b) the Self-Care Management Scale has a two-factor structure, but the primary factors loaded on a common higher-order factor; and (c) the Self-Care Confidence Scale is unidimensional. Reliability estimates for the three scales, obtained with methods compatible with each scale's dimensionality, were adequate or high. The results of the analysis demonstrate that issues of dimensionality and reliability cannot be separated. Appropriate estimates of reliability that are consistent with the dimensionality of the scale must be used. In the case of the SCHFI, coefficient alpha should not be used to assess reliability of the self-care maintenance and the self-care management scales, due to their multidimensionality. When performing psychometric evaluations, we recommend testing dimensionality before assessing reliability, as well using multiple indices of reliability, such as model-based internal consistency, composite reliability, and omega and maximal reliability coefficients. (c) 2014 Wiley Periodicals, Inc.

Barbaranelli, C., Lee, C.s., Vellone, E., Riegel, B. (2014). Dimensionality and reliability of the self-care of heart failure index scales: Further evidence from confirmatory factor analysis. RESEARCH IN NURSING & HEALTH, 37(6), 524-537 [10.1002/nur.21623].

Dimensionality and reliability of the self-care of heart failure index scales: Further evidence from confirmatory factor analysis

Vellone, E.;Riegel, B.
2014-01-01

Abstract

The Self-Care of Heart Failure Index (SCHFI) is used widely, but issues with reliability have been evident. Cronbach alpha coefficient is usually used to assess reliability, but this approach assumes a unidimensional scale. The purpose of this article is to address the dimensionality and internal consistency reliability of the SCHFI. This was a secondary analysis of data from 629 adults with heart failure enrolled in three separate studies conducted in the northeastern and northwestern United States. Following testing for scale dimensionality using confirmatory factor analysis, reliability was tested using coefficient alpha and alternative options. Confirmatory factor analysis demonstrated that: (a) the Self-Care Maintenance Scale has a multidimensional four-factor structure; (b) the Self-Care Management Scale has a two-factor structure, but the primary factors loaded on a common higher-order factor; and (c) the Self-Care Confidence Scale is unidimensional. Reliability estimates for the three scales, obtained with methods compatible with each scale's dimensionality, were adequate or high. The results of the analysis demonstrate that issues of dimensionality and reliability cannot be separated. Appropriate estimates of reliability that are consistent with the dimensionality of the scale must be used. In the case of the SCHFI, coefficient alpha should not be used to assess reliability of the self-care maintenance and the self-care management scales, due to their multidimensionality. When performing psychometric evaluations, we recommend testing dimensionality before assessing reliability, as well using multiple indices of reliability, such as model-based internal consistency, composite reliability, and omega and maximal reliability coefficients. (c) 2014 Wiley Periodicals, Inc.
2014
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-24/C - Scienze infermieristiche generali, cliniche, pediatriche e ostetrico-ginecologiche e neonatali
English
factor analysis
heart failure
instrument validation
measurement
psychometrics
reliability
self-care
Barbaranelli, C., Lee, C.s., Vellone, E., Riegel, B. (2014). Dimensionality and reliability of the self-care of heart failure index scales: Further evidence from confirmatory factor analysis. RESEARCH IN NURSING & HEALTH, 37(6), 524-537 [10.1002/nur.21623].
Barbaranelli, C; Lee, Cs; Vellone, E; Riegel, B
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Baerbaranelli_2014_Reliability_SCHFI.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 335.94 kB
Formato Adobe PDF
335.94 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/471385
Citazioni
  • ???jsp.display-item.citation.pmc??? 40
  • Scopus 105
  • ???jsp.display-item.citation.isi??? 98
social impact