Transient evoked otoacoustic emissions (TEOAEs) have been analyzed in a population of 134 ears, divided into three classes: (1) nonexposed ears in bilaterally normal hearing subjects, (2) audiometrically normal ears of subjects exposed to noise and affected by unilateral high-frequency (f>3 kHz) hearing loss in the contralateral ear, and (3) the contralateral impaired ears of the exposed subjects. The statistical distributions of global and spectral signal-to-noise ratio (SNR) were analyzed. TEOAEs were recorded both in the linear and nonlinear acquisition mode to evaluate the effectiveness of two standard averaging techniques with respect to their sensitivity to the early effects of noise exposure. Good discrimination between nonexposed and exposed ears was obtained using either the linear or the nonlinear mode. Despite its intrinsically higher SNR, the linear mode is not more sensitive than the nonlinear mode for this purpose because it is not possible to find a window for effectively cancelling the linear artifact while keeping a suitable sensitivity to the short-latency high-frequency aspect of the response. Moreover, with respect to another measurable parameter, the TEOAE latency, good discrimination is obtained only by using the nonlinear mode because, again, the linear artifact masks the high-frequency TEOAE response. © 2002 Elsevier Science B.V. All rights reserved.

Moleti, A., Sisto, R., Lucertini, M. (2002). Linear and nonlinear transient evoked otoacoustic emissions in humans exposed to noise. HEARING RESEARCH, 174, 290-295 [10.1016/S0378-5955(02)00703-7].

Linear and nonlinear transient evoked otoacoustic emissions in humans exposed to noise

MOLETI, ARTURO;
2002-01-01

Abstract

Transient evoked otoacoustic emissions (TEOAEs) have been analyzed in a population of 134 ears, divided into three classes: (1) nonexposed ears in bilaterally normal hearing subjects, (2) audiometrically normal ears of subjects exposed to noise and affected by unilateral high-frequency (f>3 kHz) hearing loss in the contralateral ear, and (3) the contralateral impaired ears of the exposed subjects. The statistical distributions of global and spectral signal-to-noise ratio (SNR) were analyzed. TEOAEs were recorded both in the linear and nonlinear acquisition mode to evaluate the effectiveness of two standard averaging techniques with respect to their sensitivity to the early effects of noise exposure. Good discrimination between nonexposed and exposed ears was obtained using either the linear or the nonlinear mode. Despite its intrinsically higher SNR, the linear mode is not more sensitive than the nonlinear mode for this purpose because it is not possible to find a window for effectively cancelling the linear artifact while keeping a suitable sensitivity to the short-latency high-frequency aspect of the response. Moreover, with respect to another measurable parameter, the TEOAE latency, good discrimination is obtained only by using the nonlinear mode because, again, the linear artifact masks the high-frequency TEOAE response. © 2002 Elsevier Science B.V. All rights reserved.
2002
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore FIS/07 - FISICA APPLICATA (A BENI CULTURALI, AMBIENTALI, BIOLOGIA E MEDICINA)
English
Con Impact Factor ISI
Exposure to noise; Hearing loss; Transient evoked otoacoustic emissions
Moleti, A., Sisto, R., Lucertini, M. (2002). Linear and nonlinear transient evoked otoacoustic emissions in humans exposed to noise. HEARING RESEARCH, 174, 290-295 [10.1016/S0378-5955(02)00703-7].
Moleti, A; Sisto, R; Lucertini, M
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/45612
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact