Herein, we report the first electrochemical microfluidic thread/paper-based analytical device (μTPAD) by harnessing the synergistic combination of embroidery as a manufacturing technique and paper-based technology. The effectiveness of the μTPAD was tested for potentiometric pH monitoring in chronic wounds. A configuration was designed for multiple analyses in chronic wounds, simply by cutting off one of the μthread–paper pads used for measurement and renewal every time the electrochemical cell was used for measurement. The electrochemical cell was constituted by conductive silver threads coated with graphite and Ag/AgCl inks, for the working and reference electrodes, respectively. The working electrode was also electrochemically modified with an iridium oxide film to sense proton activity, and the modified threads were then embroidered onto filter paper as a support. The μTPAD was successively connected to a portable miniaturized potentiostat, connected via Bluetooth Low Energy to a smartphone, with a dedicated app for potential readout to deliver a wearable device, allowing for pH monitoring in the pH range between 4 and 8, with a sensitivity of 0.056 ± 0.002 V pH−1 and a reproducibility (RSD%) equal to 8%. The accuracy of the wearable device was assessed by measuring the fluid secreted in a chronic wound near the fibula of a human leg and comparing the data with a laboratory pH meter, demonstrating the reliability of this new concept of wearable paper-based devices.

Belcastro, L., Fiore, L., Zafar, H., Simic, M., Vitiello, R., Libertini, M., et al. (2025). Embroidered paper-based electrochemical wearable device for pH monitoring in wounds. LAB ON A CHIP [10.1039/D5LC00609K].

Embroidered paper-based electrochemical wearable device for pH monitoring in wounds

Belcastro L.;Fiore L.;Arduini F.
2025-10-15

Abstract

Herein, we report the first electrochemical microfluidic thread/paper-based analytical device (μTPAD) by harnessing the synergistic combination of embroidery as a manufacturing technique and paper-based technology. The effectiveness of the μTPAD was tested for potentiometric pH monitoring in chronic wounds. A configuration was designed for multiple analyses in chronic wounds, simply by cutting off one of the μthread–paper pads used for measurement and renewal every time the electrochemical cell was used for measurement. The electrochemical cell was constituted by conductive silver threads coated with graphite and Ag/AgCl inks, for the working and reference electrodes, respectively. The working electrode was also electrochemically modified with an iridium oxide film to sense proton activity, and the modified threads were then embroidered onto filter paper as a support. The μTPAD was successively connected to a portable miniaturized potentiostat, connected via Bluetooth Low Energy to a smartphone, with a dedicated app for potential readout to deliver a wearable device, allowing for pH monitoring in the pH range between 4 and 8, with a sensitivity of 0.056 ± 0.002 V pH−1 and a reproducibility (RSD%) equal to 8%. The accuracy of the wearable device was assessed by measuring the fluid secreted in a chronic wound near the fibula of a human leg and comparing the data with a laboratory pH meter, demonstrating the reliability of this new concept of wearable paper-based devices.
15-ott-2025
Online ahead of print
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/01
Settore CHEM-01/A - Chimica analitica
English
Con Impact Factor ISI
Belcastro, L., Fiore, L., Zafar, H., Simic, M., Vitiello, R., Libertini, M., et al. (2025). Embroidered paper-based electrochemical wearable device for pH monitoring in wounds. LAB ON A CHIP [10.1039/D5LC00609K].
Belcastro, L; Fiore, L; Zafar, H; Simic, M; Vitiello, R; Libertini, M; Lista, F; Maccaruo, G; Stojanović, G; Arduini, F
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
articolo- Embroidered paper-based electrochemical wearable device for pH monitoring in wounds.pdf

solo utenti autorizzati

Descrizione: Embroidered paper-based electrochemical wearable device for pH monitoring in wounds
Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 1.41 MB
Formato Adobe PDF
1.41 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/438203
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact