Background: Differentiating Parkinson’s disease (PD) from essential tremor (ET) is often challenging, especially in early or atypical cases. Dopamine transporter (DAT) single-photon emission computed tomography (SPECT) with 123I-Ioflupane supports diagnosis, and semi-quantitative tools such as DaTQUANT® and BasGanV2™ provide objective measures. This study compared their diagnostic performance when integrated with supervised machine learning. Methods: We retrospectively analysed 123I-Ioflupane SPECT scans from 169 patients (133 PD, 36 ET). Semi-quantitative analysis was performed using DaTQUANT® v2.0 and BasGanV2™ v.2. Classification tree (ClT), k-nearest neighbour (k-NN), and support vector machine (SVM) models were trained and validated with stratified shuffle split (250 iterations). Diagnostic accuracy was compared between the two software packages. Results: All classifiers reliably distinguished PD from ET. DaTQUANT® consistently achieved higher accuracy than BasGanV2™: 93.8%, 93.2%, and 94.5% for ClT, k-NN, and SVM, respectively, versus 90.9%, 91.7%, and 91.9% for BasGanV2™ (p < 0.001). Sensitivity and specificity were also consistently higher for DaTQUANT® than BasGanV2. Class imbalance (PD > ET) was addressed using Synthetic Minority Over-sampling Technique (SMOTE). Conclusions: Machine learning analysis of 123I-Ioflupane SPECT enhances differentiation between PD and ET. DaTQUANT® outperformed BasGanV2™, suggesting greater suitability for AI-driven decision support. These findings support the integration of semi-quantitative and AI-based approaches into clinical workflows and highlight the need for harmonised methodologies in movement disorder imaging.

Palumbo, B., Filippi, L., Marongiu, A., Bianconi, F., Fravolini, M.l., Danieli, R., et al. (2025). Diagnostic Accuracy of DaTQUANT® Versus BasGanV2™ for 123I-Ioflupane Brain SPECT: A Machine Learning-Based Differentiation of Parkinson’s Disease and Essential Tremor. BIOMEDICINES, 13(10) [10.3390/biomedicines13102367].

Diagnostic Accuracy of DaTQUANT® Versus BasGanV2™ for 123I-Ioflupane Brain SPECT: A Machine Learning-Based Differentiation of Parkinson’s Disease and Essential Tremor

Filippi, Luca;
2025-09-26

Abstract

Background: Differentiating Parkinson’s disease (PD) from essential tremor (ET) is often challenging, especially in early or atypical cases. Dopamine transporter (DAT) single-photon emission computed tomography (SPECT) with 123I-Ioflupane supports diagnosis, and semi-quantitative tools such as DaTQUANT® and BasGanV2™ provide objective measures. This study compared their diagnostic performance when integrated with supervised machine learning. Methods: We retrospectively analysed 123I-Ioflupane SPECT scans from 169 patients (133 PD, 36 ET). Semi-quantitative analysis was performed using DaTQUANT® v2.0 and BasGanV2™ v.2. Classification tree (ClT), k-nearest neighbour (k-NN), and support vector machine (SVM) models were trained and validated with stratified shuffle split (250 iterations). Diagnostic accuracy was compared between the two software packages. Results: All classifiers reliably distinguished PD from ET. DaTQUANT® consistently achieved higher accuracy than BasGanV2™: 93.8%, 93.2%, and 94.5% for ClT, k-NN, and SVM, respectively, versus 90.9%, 91.7%, and 91.9% for BasGanV2™ (p < 0.001). Sensitivity and specificity were also consistently higher for DaTQUANT® than BasGanV2. Class imbalance (PD > ET) was addressed using Synthetic Minority Over-sampling Technique (SMOTE). Conclusions: Machine learning analysis of 123I-Ioflupane SPECT enhances differentiation between PD and ET. DaTQUANT® outperformed BasGanV2™, suggesting greater suitability for AI-driven decision support. These findings support the integration of semi-quantitative and AI-based approaches into clinical workflows and highlight the need for harmonised methodologies in movement disorder imaging.
26-set-2025
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-22/A - Diagnostica per immagini e radioterapia
English
Parkinson’s disease; DaTQUANT®; BasGanV2™; dopamine transporters; SPECT; 123I-Ioflupane; machine learning; artificial intelligence; rehabilitation; movement disorders
Palumbo, B., Filippi, L., Marongiu, A., Bianconi, F., Fravolini, M.l., Danieli, R., et al. (2025). Diagnostic Accuracy of DaTQUANT® Versus BasGanV2™ for 123I-Ioflupane Brain SPECT: A Machine Learning-Based Differentiation of Parkinson’s Disease and Essential Tremor. BIOMEDICINES, 13(10) [10.3390/biomedicines13102367].
Palumbo, B; Filippi, L; Marongiu, A; Bianconi, F; Fravolini, Ml; Danieli, R; Frantellizzi, V; De Vincentis, G; Spanu, A; Nuvoli, S
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
biomedicines-13-023671.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 2.01 MB
Formato Adobe PDF
2.01 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/434845
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact