Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 LiMoO crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of LiMoO cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a LiMoO light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

Null, N., Alfonso, K., Armatol, A., Augier, C., Avignone, F.t., Azzolini, O., et al. (2025). A gravity-based mounting approach for large-scale cryogenic calorimeter arrays. EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 85(9) [10.1140/epjc/s10052-025-14613-z].

A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

Caracciolo, V.;
2025-09-02

Abstract

Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 LiMoO crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of LiMoO cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a LiMoO light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.
2-set-2025
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore FIS/04
Settore PHYS-01/A - Fisica sperimentale delle interazioni fondamentali e applicazioni
English
Con Impact Factor ISI
Cryogenic calorimeters; CUPID experiment; Neutrinoless double-beta decay; Gravity-based assembly; Li₂MoO₄ detectors; Majorana; Neutrono
https://link.springer.com/article/10.1140/epjc/s10052-025-14613-z?utm_source=rct_congratemailt&utm_medium=email&utm_campaign=oa_20250902&utm_content=10.1140/epjc/s10052-025-14613-z#citeas
Null, N., Alfonso, K., Armatol, A., Augier, C., Avignone, F.t., Azzolini, O., et al. (2025). A gravity-based mounting approach for large-scale cryogenic calorimeter arrays. EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS, 85(9) [10.1140/epjc/s10052-025-14613-z].
Null, N; Alfonso, K; Armatol, A; Augier, C; Avignone, Ft; Azzolini, O; Barabash, As; Bari, G; Barrera, A; Baudin, D; Bellini, F; Benato, G; Benussi, L...espandi
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
s10052-025-14613-z.pdf

accesso aperto

Descrizione: Articolo
Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.83 MB
Formato Adobe PDF
1.83 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/430605
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact