Purpose: To systematically analyze the accuracy of autonomous dental implant robotic (ADIR) surgery for dental implant placement. Materials and methods: PubMed, Embase, and Cochrane CENTRAL were searched on February 21, 2024. Any clinical studies, with the exception of case reports, assessing ADIR accuracy by superimposing preoperative digital planning with postoperative CBCT images were included. The risk of bias was assessed, and a meta-analysis was performed using a random-effect model to evaluate linear and angular deviations between planned and placed implants. Results: Data from six clinical studies reporting ADIR accuracy in 96 patients with 299 dental implants were included (102 implants in 69 partially edentulous patients, 197 implants in 27 complete-arch scenarios). The meta analysis at the implant level reported a mean overall accuracy of ADIR of 0.60 mm (95% CI [0.5133; 0.6965]) at the platform and 0.63 mm (95% CI [0.5663; 0.6909]) at the apex and 1.242 degrees (95% CI [1.2182; 1.6320]) of angular deviation. ADIR accuracy resulted in significantly higher values than static and dynamic computer-assisted implant surgery. Conclusions: Within the limitations of this review, ADIR surgery has shown to be feasible for placing implants in both partially and completely edentulous patients, achieving consistent mean linear and angular deviations of approximately 0.6 mm and 1.40 degrees, respectively. However, clinical practicality of ADIR surgery remains cumbersome, with well-trained operators needed to plan and assist ADIR procedures as well as a technical expert providing backup control.

Pozzi, A., Carosi, P., Lorenzi, C., Chow, J., Wang, H., Gallucci, G.o. (2025). In-Vivo Accuracy of Autonomous Dental Implant Robotic Surgery: Systematic Review and Meta-Analysis. THE INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1-9 [10.11607/jomi.11238].

In-Vivo Accuracy of Autonomous Dental Implant Robotic Surgery: Systematic Review and Meta-Analysis

Pozzi, Alessandro
Writing – Review & Editing
;
Carosi, Paolo;Lorenzi, Claudia;
2025-05-06

Abstract

Purpose: To systematically analyze the accuracy of autonomous dental implant robotic (ADIR) surgery for dental implant placement. Materials and methods: PubMed, Embase, and Cochrane CENTRAL were searched on February 21, 2024. Any clinical studies, with the exception of case reports, assessing ADIR accuracy by superimposing preoperative digital planning with postoperative CBCT images were included. The risk of bias was assessed, and a meta-analysis was performed using a random-effect model to evaluate linear and angular deviations between planned and placed implants. Results: Data from six clinical studies reporting ADIR accuracy in 96 patients with 299 dental implants were included (102 implants in 69 partially edentulous patients, 197 implants in 27 complete-arch scenarios). The meta analysis at the implant level reported a mean overall accuracy of ADIR of 0.60 mm (95% CI [0.5133; 0.6965]) at the platform and 0.63 mm (95% CI [0.5663; 0.6909]) at the apex and 1.242 degrees (95% CI [1.2182; 1.6320]) of angular deviation. ADIR accuracy resulted in significantly higher values than static and dynamic computer-assisted implant surgery. Conclusions: Within the limitations of this review, ADIR surgery has shown to be feasible for placing implants in both partially and completely edentulous patients, achieving consistent mean linear and angular deviations of approximately 0.6 mm and 1.40 degrees, respectively. However, clinical practicality of ADIR surgery remains cumbersome, with well-trained operators needed to plan and assist ADIR procedures as well as a technical expert providing backup control.
6-mag-2025
Online ahead of print
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-16/A - Malattie odontostomatologiche
English
Con Impact Factor ISI
accuracy
autonomous dental implant robotic surgery
dental implant
digital dentistry
implant guides
meta- analysis
robotic surgery
Pozzi, A., Carosi, P., Lorenzi, C., Chow, J., Wang, H., Gallucci, G.o. (2025). In-Vivo Accuracy of Autonomous Dental Implant Robotic Surgery: Systematic Review and Meta-Analysis. THE INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1-9 [10.11607/jomi.11238].
Pozzi, A; Carosi, P; Lorenzi, C; Chow, J; Wang, H; Gallucci, Go
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
2025 Pozzi, JOMI Robotics.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 4.17 MB
Formato Adobe PDF
4.17 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/426547
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact