Background Recent technologies enable real-time 3-dimensional intracardiac echocardiography (ICE) with the advantages of 2-dimensional ICE and imaging capabilities of transesophageal echocardiography. The purpose of this study is to evaluate the real-world, multicenter safety and performance of a novel 3-dimensional ICE system in a variety of cardiac interventions used in standard clinical practice.Methods This prospective, multicenter, observational, single-arm study enrolled patients who were scheduled for an invasive cardiac procedure involving guidance with ICE and followed until discharge or <= 48 hours postprocedure. Intracardiac imaging was performed with the 3-dimensional ICE catheter, VeriSight Pro (Philips Inc.). Fluoroscopy was used in all cases and transesophageal echocardiography was used in some cases. The primary safety end point was device-related adverse events. The primary efficacy end point included technical success, imaging success, and clinical success.Results Between October 2021 and November 2022, 155 patients were enrolled and screened. Percutaneous interventions performed included atrial septal defect/patent foramen ovale closures, left atrial appendage occlusion, catheter ablations, and valve procedures. No adverse events were related to the device or procedure. The technical, imaging, and clinical success rates were 98.7% (95% CI, 95.4%-99.8%), 96.1% (95% CI, 91.8%-98.6%), 94.8% (95% CI, 91.8%-98.6%), respectively. Overall, the VeriSight Pro ICE image quality was assessed to be "acceptable" or greater in relation to reference image modality among 96.2% (149 of 155) of procedures.Conclusions VeriSight ICE imaging is safe and effective in the guidance of a wide variety of percutaneous cardiovascular procedures and has provided successful and high-quality imaging of cardiac structures.

Adnan Alkhouli, M., Carroll, J.d., Desai, A.a., Gao, Y., Xiong, T., Natale, A., et al. (2025). Multicenter Experience With a Novel Real‐Time 3‐Dimensional Intracardiac Echocardiography Catheter to Guide Interventional Cardiac Procedures. JOURNAL OF THE AMERICAN HEART ASSOCIATION. CARDIOVASCULAR AND CEREBROVASCULAR DISEASE, 14(6) [10.1161/JAHA.124.037019].

Multicenter Experience With a Novel Real‐Time 3‐Dimensional Intracardiac Echocardiography Catheter to Guide Interventional Cardiac Procedures

Andrea Natale;
2025-01-01

Abstract

Background Recent technologies enable real-time 3-dimensional intracardiac echocardiography (ICE) with the advantages of 2-dimensional ICE and imaging capabilities of transesophageal echocardiography. The purpose of this study is to evaluate the real-world, multicenter safety and performance of a novel 3-dimensional ICE system in a variety of cardiac interventions used in standard clinical practice.Methods This prospective, multicenter, observational, single-arm study enrolled patients who were scheduled for an invasive cardiac procedure involving guidance with ICE and followed until discharge or <= 48 hours postprocedure. Intracardiac imaging was performed with the 3-dimensional ICE catheter, VeriSight Pro (Philips Inc.). Fluoroscopy was used in all cases and transesophageal echocardiography was used in some cases. The primary safety end point was device-related adverse events. The primary efficacy end point included technical success, imaging success, and clinical success.Results Between October 2021 and November 2022, 155 patients were enrolled and screened. Percutaneous interventions performed included atrial septal defect/patent foramen ovale closures, left atrial appendage occlusion, catheter ablations, and valve procedures. No adverse events were related to the device or procedure. The technical, imaging, and clinical success rates were 98.7% (95% CI, 95.4%-99.8%), 96.1% (95% CI, 91.8%-98.6%), 94.8% (95% CI, 91.8%-98.6%), respectively. Overall, the VeriSight Pro ICE image quality was assessed to be "acceptable" or greater in relation to reference image modality among 96.2% (149 of 155) of procedures.Conclusions VeriSight ICE imaging is safe and effective in the guidance of a wide variety of percutaneous cardiovascular procedures and has provided successful and high-quality imaging of cardiac structures.
2025
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-07/B - Malattie dell'apparato cardiovascolare
English
3‐dimensional
anesthesia
intracardiac echocardiography
Adnan Alkhouli, M., Carroll, J.d., Desai, A.a., Gao, Y., Xiong, T., Natale, A., et al. (2025). Multicenter Experience With a Novel Real‐Time 3‐Dimensional Intracardiac Echocardiography Catheter to Guide Interventional Cardiac Procedures. JOURNAL OF THE AMERICAN HEART ASSOCIATION. CARDIOVASCULAR AND CEREBROVASCULAR DISEASE, 14(6) [10.1161/JAHA.124.037019].
Adnan Alkhouli, M; Carroll, Jd; Desai, Aa; Gao, Y; Xiong, T; Natale, A; Inglessis‐azuaje, I; Knight, Bp
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/416712
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact