Nuclear fusion stands out as a promising energy source, with numerous experimental reactors currently operational and larger ones in various stages of construction. As reactor dimensions increase, the precise measurement of the plasma total emitted radiation becomes increasingly crucial. This quantity not only helps in evaluating tokamak power balances but also enhances the understanding of the underlying physics in different processes. To optimize the performance of large nuclear fusion reactors, for example, various radiative scenarios have been proposed. These involve injecting gas into the plasma to induce radiation emission, thereby reducing the heat load on the reactor plasma facing components. Additionally, analysing the radiation pattern within the plasma provides valuable insights into impurity transport. A key technique for extracting information on plasma radiation is tomography reconstruction based on bolometric measurements. Addressing the resulting inverse problem, an effective approach involves utilizing maximum likelihood methods, which not only facilitates the reconstruction but also offers an estimation of the reconstruction errors. This study aims to investigate the impact of the bolometer diagnostic geometry on the reconstruction performance, a critical aspect for designing bolometers for future fusion machines. Due to limited space availability, bolometer systems present a restricted number of projections, rendering the optimization of the geometry fundamental for minimizing the sources of error. The analysis performed consists of reconstructing synthetic images in different geometries, varying angles of view and the number of lines of sight. Finally, an optimal criterion is defined to guide the selection of the geometry, ensuring robust reconstruction with minimal susceptibility to measurement errors.

Wyss, I., D’Agostino, V., Murari, A., Gaudio, P., Gelfusa, M., Apruzzese, G., et al. (2025). Proposal of a criterion to select the layout of bolometric diagnostics for robust plasma radiation reconstruction in fusion devices. FUSION ENGINEERING AND DESIGN [10.1016/j.fusengdes.2025.114940].

Proposal of a criterion to select the layout of bolometric diagnostics for robust plasma radiation reconstruction in fusion devices

Ivan Wyss
;
Valentina D’Agostino;Pasquale Gaudio
Supervision
;
Michela Gelfusa;Riccardo Rossi
2025-01-01

Abstract

Nuclear fusion stands out as a promising energy source, with numerous experimental reactors currently operational and larger ones in various stages of construction. As reactor dimensions increase, the precise measurement of the plasma total emitted radiation becomes increasingly crucial. This quantity not only helps in evaluating tokamak power balances but also enhances the understanding of the underlying physics in different processes. To optimize the performance of large nuclear fusion reactors, for example, various radiative scenarios have been proposed. These involve injecting gas into the plasma to induce radiation emission, thereby reducing the heat load on the reactor plasma facing components. Additionally, analysing the radiation pattern within the plasma provides valuable insights into impurity transport. A key technique for extracting information on plasma radiation is tomography reconstruction based on bolometric measurements. Addressing the resulting inverse problem, an effective approach involves utilizing maximum likelihood methods, which not only facilitates the reconstruction but also offers an estimation of the reconstruction errors. This study aims to investigate the impact of the bolometer diagnostic geometry on the reconstruction performance, a critical aspect for designing bolometers for future fusion machines. Due to limited space availability, bolometer systems present a restricted number of projections, rendering the optimization of the geometry fundamental for minimizing the sources of error. The analysis performed consists of reconstructing synthetic images in different geometries, varying angles of view and the number of lines of sight. Finally, an optimal criterion is defined to guide the selection of the geometry, ensuring robust reconstruction with minimal susceptibility to measurement errors.
2025
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore FIS/01
Settore ING-IND/18 - Fisica dei Reattori Nucleari
Settore PHYS-03/A - Fisica sperimentale della materia e applicazioni
English
Bolometry; Plasma Radiation; Tomography; Plasma Diagnostic
Wyss, I., D’Agostino, V., Murari, A., Gaudio, P., Gelfusa, M., Apruzzese, G., et al. (2025). Proposal of a criterion to select the layout of bolometric diagnostics for robust plasma radiation reconstruction in fusion devices. FUSION ENGINEERING AND DESIGN [10.1016/j.fusengdes.2025.114940].
Wyss, I; D’Agostino, V; Murari, A; Gaudio, P; Gelfusa, M; Apruzzese, G; Rossi, R
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0920379625001401-main.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 7.46 MB
Formato Adobe PDF
7.46 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/415443
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact