Positioning of the ventricular catheter is safe using standard techniques, but in some cases there may be failure of a shunt because of incorrect placement. We carried out CT at the end of the surgical operation on 10 patients who had undergone cerebrospinal fluid shunting while still anaesthetized. In three cases a malpositioned catheter was detected. Immediate reoperation allowed readjustment of the ventricular catheter. Early postoperative CT appears to be useful for verifying correct placement.
Missori, P., Artizzu, S., Salvati, M. (2000). Immediate postoperative CT to assess the correct positioning of a ventricular catheter. BRITISH JOURNAL OF NEUROSURGERY, 14(1), 44-45 [10.1080/02688690042906].
Immediate postoperative CT to assess the correct positioning of a ventricular catheter
Salvati, M.
2000-01-01
Abstract
Positioning of the ventricular catheter is safe using standard techniques, but in some cases there may be failure of a shunt because of incorrect placement. We carried out CT at the end of the surgical operation on 10 patients who had undergone cerebrospinal fluid shunting while still anaesthetized. In three cases a malpositioned catheter was detected. Immediate reoperation allowed readjustment of the ventricular catheter. Early postoperative CT appears to be useful for verifying correct placement.| File | Dimensione | Formato | |
|---|---|---|---|
|
02688690042906.pdf
solo utenti autorizzati
Tipologia:
Versione Editoriale (PDF)
Licenza:
Copyright dell'editore
Dimensione
210.53 kB
Formato
Adobe PDF
|
210.53 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.