Background: Quantitative measurement of HIV-1 RNA levels in plasma ('viral load') plays a central role in clinical management. The choice of assay platform can influence results and treatment decisions. Objective: To compare the analytical performance of the new TMA-based Hologic Aptima® HIV-1 Quant Dx assay with that of three PCR-based assays: Abbott RealTime HIV-1, Qiagen Artus® HI Virus-1 QS-RGQ, and Roche CAP/CTM HIV-1 Test v2. Study design: Assay performance was evaluated using Acrometrix HIV-1 RNA Standard panels; the 3rd WHO HIV-1 RNA International Standard (12-500. copies/ml; 6 dilutions; 9 replicates); and plasma samples from 191 HIV-positive patients. Results: Aptima showed high (>0.99) precision, accuracy and concordance with the Acrometrix Standards across a wide dynamic range (2.0-6.7 log10copies/ml). Variance caused up to 2.1 (Aptima), 1.7 (RealTime), 7.5 (Artus), and 1.9 (CAP/CTM) fold changes in the International Standard quantifications at 50-500copies/ml. HIV-1 RNA detection rates in plasma samples were 141/191 (74%), 119/191 (62%), 108/191 (57%), and 145/191 (76%) for Aptima, RealTime, Artus and CAP/CTM, respectively. For categorising samples either side of 50 copies/ml, Aptima had excellent agreement with RealTime (kappa 0.92; 95% CI 0.87-0.98); lowest agreement was with Artus (kappa 0.79; 95%CI 0.70-0.88). Aptima quantifications were mean 0.12 and 0.06 log10copies/ml higher compared with RealTime and CAP/CTM, respectively, and 0.05 log10copies/ml lower compared with Artus. Limits of agreement were narrowest when comparing Aptima to RealTime. Conclusions: The new Aptima HIV assay is sensitive, precise, and accurate. HIV assays exhibit discordance at low HIV-1 RNA copy numbers.

Hopkins, M., Hau, S., Tiernan, C., Papadimitropoulos, A., Chawla, A., Beloukas, A., et al. (2015). Comparative performance of the new Aptima HIV-1 Quant Dx assay with three commercial PCR-based HIV-1 RNA quantitation assays. JOURNAL OF CLINICAL VIROLOGY, 69, 56-62 [10.1016/j.jcv.2015.05.020].

Comparative performance of the new Aptima HIV-1 Quant Dx assay with three commercial PCR-based HIV-1 RNA quantitation assays

Geretti, A. M.
2015-01-01

Abstract

Background: Quantitative measurement of HIV-1 RNA levels in plasma ('viral load') plays a central role in clinical management. The choice of assay platform can influence results and treatment decisions. Objective: To compare the analytical performance of the new TMA-based Hologic Aptima® HIV-1 Quant Dx assay with that of three PCR-based assays: Abbott RealTime HIV-1, Qiagen Artus® HI Virus-1 QS-RGQ, and Roche CAP/CTM HIV-1 Test v2. Study design: Assay performance was evaluated using Acrometrix HIV-1 RNA Standard panels; the 3rd WHO HIV-1 RNA International Standard (12-500. copies/ml; 6 dilutions; 9 replicates); and plasma samples from 191 HIV-positive patients. Results: Aptima showed high (>0.99) precision, accuracy and concordance with the Acrometrix Standards across a wide dynamic range (2.0-6.7 log10copies/ml). Variance caused up to 2.1 (Aptima), 1.7 (RealTime), 7.5 (Artus), and 1.9 (CAP/CTM) fold changes in the International Standard quantifications at 50-500copies/ml. HIV-1 RNA detection rates in plasma samples were 141/191 (74%), 119/191 (62%), 108/191 (57%), and 145/191 (76%) for Aptima, RealTime, Artus and CAP/CTM, respectively. For categorising samples either side of 50 copies/ml, Aptima had excellent agreement with RealTime (kappa 0.92; 95% CI 0.87-0.98); lowest agreement was with Artus (kappa 0.79; 95%CI 0.70-0.88). Aptima quantifications were mean 0.12 and 0.06 log10copies/ml higher compared with RealTime and CAP/CTM, respectively, and 0.05 log10copies/ml lower compared with Artus. Limits of agreement were narrowest when comparing Aptima to RealTime. Conclusions: The new Aptima HIV assay is sensitive, precise, and accurate. HIV assays exhibit discordance at low HIV-1 RNA copy numbers.
2015
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-10/B - Malattie infettive
English
Analytical performance
Aptima HIV-1 Quant Dx assay
HIV-1 quantitation
TMA
Viral load
Hopkins, M., Hau, S., Tiernan, C., Papadimitropoulos, A., Chawla, A., Beloukas, A., et al. (2015). Comparative performance of the new Aptima HIV-1 Quant Dx assay with three commercial PCR-based HIV-1 RNA quantitation assays. JOURNAL OF CLINICAL VIROLOGY, 69, 56-62 [10.1016/j.jcv.2015.05.020].
Hopkins, M; Hau, S; Tiernan, C; Papadimitropoulos, A; Chawla, A; Beloukas, A; Geretti, Am
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/410543
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 39
social impact