The LightCycler polymerase chain reaction (PCR) is a sensitive assay for the detection of Herpes simplex virus (HSV) DNA in muco-cutaneous swabs. Software-based analysis of the probe melting temperature (Tm) can be used to discriminate between HSV types (HSV-1 and HSV-2). Among 76 HSV DNA positive genital swabs, atypical Tms were observed in 14 (18%). The 14 samples were all typed as HSV-2 by sequence alignment. In 4/14 samples, the atypical Tm was associated with sequence variation at the probe-binding site. Among 10 samples with conserved sequences, Tms were influenced by the specimen preparation method prior to PCR. These findings indicate that multiple factors including, but not limited to sequence variation complicate melting curve analysis following real-time PCR. Alternative typing methods are recommended for specimens with atypical melting curves.

Ramaswamy, M., Smith, M., Geretti, A.m. (2005). Detection and typing of herpes simplex DNA in genital swabs by real-time polymerase chain reaction. JOURNAL OF VIROLOGICAL METHODS, 126(1-2), 203-206 [10.1016/j.jviromet.2005.02.012].

Detection and typing of herpes simplex DNA in genital swabs by real-time polymerase chain reaction

Geretti, A. M.
2005-01-01

Abstract

The LightCycler polymerase chain reaction (PCR) is a sensitive assay for the detection of Herpes simplex virus (HSV) DNA in muco-cutaneous swabs. Software-based analysis of the probe melting temperature (Tm) can be used to discriminate between HSV types (HSV-1 and HSV-2). Among 76 HSV DNA positive genital swabs, atypical Tms were observed in 14 (18%). The 14 samples were all typed as HSV-2 by sequence alignment. In 4/14 samples, the atypical Tm was associated with sequence variation at the probe-binding site. Among 10 samples with conserved sequences, Tms were influenced by the specimen preparation method prior to PCR. These findings indicate that multiple factors including, but not limited to sequence variation complicate melting curve analysis following real-time PCR. Alternative typing methods are recommended for specimens with atypical melting curves.
2005
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-10/B - Malattie infettive
English
HSV-2
Real-time PCR
Sequencing
Ramaswamy, M., Smith, M., Geretti, A.m. (2005). Detection and typing of herpes simplex DNA in genital swabs by real-time polymerase chain reaction. JOURNAL OF VIROLOGICAL METHODS, 126(1-2), 203-206 [10.1016/j.jviromet.2005.02.012].
Ramaswamy, M; Smith, M; Geretti, Am
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
hsv.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 233 kB
Formato Adobe PDF
233 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/410467
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 3
social impact