The analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche COBAS TaqMan assays. Two different protocols used during the testing period with and without a pre-m1000 RNA isolation spin were compared. The difference proved to be nonsignificant. A uracil-N-glycosylase (UNG) contamination control option in the HCV test for previous Roche COBAS Amplicor users was evaluated. It proved to decrease amplicon carryover by 100-fold independent of the amplicon input concentration. The protocol including UNG proved to overcome problems with false-positive negative controls. Comparison with other assays revealed only minor differences. The largest difference was observed between the Abbott HCV RealTime assay and the Roche COBAS Amplicor HCV Monitor version 2.0 assay

Schutten, M., Peters, D., Back, N., Beld, M., Beuselinck, K., Foulongne, V., et al. (2007). Multicenter evaluation of the new Abbott Realtime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA. JOURNAL OF CLINICAL MICROBIOLOGY, 45(6), 1712-1717 [10.1128/JCM.02385-06].

Multicenter evaluation of the new Abbott Realtime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA

Geretti, A. M.;
2007-01-01

Abstract

The analytical performances of the new Abbott RealTime hepatitis C virus (HCV) and human immunodeficiency virus type 1 viral load assays were compared at nine laboratories with different competitor assays. These included the Abbott LcX, Bayer Versant bDNA, Roche COBAS Amplicor, and Roche COBAS TaqMan assays. Two different protocols used during the testing period with and without a pre-m1000 RNA isolation spin were compared. The difference proved to be nonsignificant. A uracil-N-glycosylase (UNG) contamination control option in the HCV test for previous Roche COBAS Amplicor users was evaluated. It proved to decrease amplicon carryover by 100-fold independent of the amplicon input concentration. The protocol including UNG proved to overcome problems with false-positive negative controls. Comparison with other assays revealed only minor differences. The largest difference was observed between the Abbott HCV RealTime assay and the Roche COBAS Amplicor HCV Monitor version 2.0 assay
2007
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-10/B - Malattie infettive
English
Schutten, M., Peters, D., Back, N., Beld, M., Beuselinck, K., Foulongne, V., et al. (2007). Multicenter evaluation of the new Abbott Realtime assays for quantitative detection of human immunodeficiency virus type 1 and hepatitis C virus RNA. JOURNAL OF CLINICAL MICROBIOLOGY, 45(6), 1712-1717 [10.1128/JCM.02385-06].
Schutten, M; Peters, D; Back, Nkt; Beld, M; Beuselinck, K; Foulongne, V; Geretti, Am; Pandiani, L; Tiemann, C; Niesters, Hgm
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Multicenter Evaluation.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 244.05 kB
Formato Adobe PDF
244.05 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/410163
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 45
  • ???jsp.display-item.citation.isi??? 40
social impact