AIM: This was to correlate the dosimetric evaluation with high diagnostic accuracy by suggesting a protocol that significantly reduces the dose administered by a Dentascan exam without affecting diagnostic accuracy. MATERIALS AND METHODS: 17 patients were selected consecutively (7 males and 10 females) of a mean age of 11.2 (8-14 years) who sought orthodontic treatment. They needed CT control before and after treatment with RME to evaluate impacted canines. The study was performed using a multidetector 16-rows CT with two protocols that provided 2 different KV acquisition parameters: 80 KV or 120 KV. Radiation dose was evaluated in two ways: CTDI and DLP. Image quality was rated and the results were compared to identify significant differences in terms of image quality, radiation exposure and presence of artefacts. RESULTS: The 80 KV scanning has a significantly lower effective radiation dose compared to the 120 KV scanning (p <0.05). The images of all patients were used for comparing the protocols in terms of image quality. The mean scores for the 80 KV scanning images were 4.18 +/-0.81 and 4.41 +/-0.80 for dose obtained by 120 KV scanning. The median image quality was 4 (good) for both protocols. The 80 KV protocol allowed, as well as the 120 KV, a careful analysis by the orthodontist and the dental surgeon that together, based on this images, can choose the best line of treatment between several available options. CONCLUSION: 80 KV protocols compared with 120 KV protocols resulted in reduced total radiation dose without relevant loss of diagnostic image information and quality. The images were good enough to obtain information about the exact position of impacted teeth and to plan the best line of surgical treatment and mechanotherapy strategy.

Ballanti, F., Lione, R., Fiaschetti, V., Fanucci, E., Cozza, P. (2008). Low-dose CT protocol for orthodontic diagnosis. EUROPEAN JOURNAL OF PAEDIATRIC DENTISTRY, 9(2), 65-70.

Low-dose CT protocol for orthodontic diagnosis.

Lione,R;FIASCHETTI, VALERIA;FANUCCI, EZIO;COZZA, PAOLA
2008-01-01

Abstract

AIM: This was to correlate the dosimetric evaluation with high diagnostic accuracy by suggesting a protocol that significantly reduces the dose administered by a Dentascan exam without affecting diagnostic accuracy. MATERIALS AND METHODS: 17 patients were selected consecutively (7 males and 10 females) of a mean age of 11.2 (8-14 years) who sought orthodontic treatment. They needed CT control before and after treatment with RME to evaluate impacted canines. The study was performed using a multidetector 16-rows CT with two protocols that provided 2 different KV acquisition parameters: 80 KV or 120 KV. Radiation dose was evaluated in two ways: CTDI and DLP. Image quality was rated and the results were compared to identify significant differences in terms of image quality, radiation exposure and presence of artefacts. RESULTS: The 80 KV scanning has a significantly lower effective radiation dose compared to the 120 KV scanning (p <0.05). The images of all patients were used for comparing the protocols in terms of image quality. The mean scores for the 80 KV scanning images were 4.18 +/-0.81 and 4.41 +/-0.80 for dose obtained by 120 KV scanning. The median image quality was 4 (good) for both protocols. The 80 KV protocol allowed, as well as the 120 KV, a careful analysis by the orthodontist and the dental surgeon that together, based on this images, can choose the best line of treatment between several available options. CONCLUSION: 80 KV protocols compared with 120 KV protocols resulted in reduced total radiation dose without relevant loss of diagnostic image information and quality. The images were good enough to obtain information about the exact position of impacted teeth and to plan the best line of surgical treatment and mechanotherapy strategy.
2008
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/36 - DIAGNOSTICA PER IMMAGINI E RADIOTERAPIA
Settore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE
Settore MED/50 - SCIENZE TECNICHE MEDICHE APPLICATE
English
Con Impact Factor ISI
PMID: 18605887
Ballanti, F., Lione, R., Fiaschetti, V., Fanucci, E., Cozza, P. (2008). Low-dose CT protocol for orthodontic diagnosis. EUROPEAN JOURNAL OF PAEDIATRIC DENTISTRY, 9(2), 65-70.
Ballanti, F; Lione, R; Fiaschetti, V; Fanucci, E; Cozza, P
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
17.Low-Dose CT protocol for orthodontic diagnosis..pdf

accesso aperto

Descrizione: articolo principale
Dimensione 49.91 kB
Formato Adobe PDF
49.91 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/40935
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 17
social impact