Background: the Cocoon patent foramen ovale (PFO) Occluder is a new generation nitinol alloy double-disk device coated with nanoplatinum, likely useful in patients with nickel hypersensitivity. Early results and mid-term outcomes of this device in percutaneous PFO closure are missing. Aims: to assess the preliminary ecacy and safety profile of PFO closure with Cocoon device in an Italian multi-center registry. Methods: This is a prospective registry of 189 consecutive adult patients treated with the Cocoon PFO Occluder at 15 Italian centers from May 2017 till May 2020. Patients were followed up for 2 years. Results: closure of the PFO with Cocoon Occluder was carried out successfully in all patients, with complete closure without residual shunt in 94.7% of the patients and minimal shunt in 5.3%. Except from a case of paroxysmal supraventricular tachycardia and a major vascular bleeding, no procedural and in-hospital device-related complications occurred. No patient developed cardiac erosions, allergic reactions to nickel, or any other major complications during the follow-up. During the follow-up period, 2 cases of new-onset atrial fibrillation occurred within thirty-d

Testa, L., Popolo Rubbio, A., Squillace, M., Albano, F., Cesario, V., Casenghi, M., et al. (2023). Patent foramen ovale occlusion with the Cocoon PFO Occluder. The PROS-IT collaborative project. FRONTIERS IN CARDIOVASCULAR MEDICINE, 9 [10.3389/fcvm.2022.1064026].

Patent foramen ovale occlusion with the Cocoon PFO Occluder. The PROS-IT collaborative project

Ussia G. P.;Sangiorgi G.;
2023-01-01

Abstract

Background: the Cocoon patent foramen ovale (PFO) Occluder is a new generation nitinol alloy double-disk device coated with nanoplatinum, likely useful in patients with nickel hypersensitivity. Early results and mid-term outcomes of this device in percutaneous PFO closure are missing. Aims: to assess the preliminary ecacy and safety profile of PFO closure with Cocoon device in an Italian multi-center registry. Methods: This is a prospective registry of 189 consecutive adult patients treated with the Cocoon PFO Occluder at 15 Italian centers from May 2017 till May 2020. Patients were followed up for 2 years. Results: closure of the PFO with Cocoon Occluder was carried out successfully in all patients, with complete closure without residual shunt in 94.7% of the patients and minimal shunt in 5.3%. Except from a case of paroxysmal supraventricular tachycardia and a major vascular bleeding, no procedural and in-hospital device-related complications occurred. No patient developed cardiac erosions, allergic reactions to nickel, or any other major complications during the follow-up. During the follow-up period, 2 cases of new-onset atrial fibrillation occurred within thirty-d
2023
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-07/B - Malattie dell'apparato cardiovascolare
English
Testa, L., Popolo Rubbio, A., Squillace, M., Albano, F., Cesario, V., Casenghi, M., et al. (2023). Patent foramen ovale occlusion with the Cocoon PFO Occluder. The PROS-IT collaborative project. FRONTIERS IN CARDIOVASCULAR MEDICINE, 9 [10.3389/fcvm.2022.1064026].
Testa, L; Popolo Rubbio, A; Squillace, M; Albano, F; Cesario, V; Casenghi, M; Tarantini, G; Pagnotta, P; Ielasi, A; Popusoi, G; Paloscia, L; Durante, ...espandi
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Patent foramen ovale.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 435.89 kB
Formato Adobe PDF
435.89 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/409306
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 3
social impact