objectives to evaluate the results of isolated left subclavian artery in-situ fenestration (ISF) during 'zone 2' thoracic endovascular aortic repair (TEVAR) using a new adjustable needle puncturing device system. methods It is a multicentre, retrospective, physician-initiated cohort study of patients treated from 28 july 2021 to 3 april 2024. Inclusion criteria were isolate left subclavian artery revascularization for elective or urgent/emergent 'zone 2' TEVAR. the primary outcome was technical success and freedom from ISF TEVAR-related reintervention or endoleak. results we treated 50 patients: 28 (56.0%) atherosclerotic thoracic aneurysms, 12 (24.0%) type B aortic dissection and 10 (20.0%) penetrating aortic ulcers. elective intervention was carried out in 46 (92.0%) cases. ISF was successful in all cases, with a procedural primary technical success in 47 (94.0%) cases. the median time of intervention was 184 min (interquartile range 135-220) with a median fenestration time of 20 min (interquartile range 13-35). operative mortality did not occur. we observed 1 case of spinal cord ischaemia and 2 cases of bilateral posterior non-disabling stroke. mortality at 30 days occurred in 1 (2.0%) patient (not aorta-related). the median follow-up was 4 months (interquartile range 1-12.25). bridging stent graft patency was 100% with no ISF-related endoleak. ISF-related reintervention was never required conclusions ISF TEVAR using the ankura (TM)-II device with the self-centring adjustable needle system showed high technical success, promising stability and stable aortic-related outcomes. owing to these results, it represents a safe and effective alternative for standard 'zone 2' TEVAR.
Piffaretti, G., Gaggiano, A., Pratesi, G., Tolva, V., Pacini, D., Pulli, R., et al. (2024). Preliminary experience of the isolate left subclavian artery in-situ fenestration during ‘zone 2’ thoracic endovascular aortic repair. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 66(4) [10.1093/ejcts/ezae332].
Preliminary experience of the isolate left subclavian artery in-situ fenestration during ‘zone 2’ thoracic endovascular aortic repair
Pratesi, Giovanni;Pratesi, Giovanni;Ippoliti, Arnaldo;Fazzini, Stefano;Tinelli, Giovanni;
2024-10-01
Abstract
objectives to evaluate the results of isolated left subclavian artery in-situ fenestration (ISF) during 'zone 2' thoracic endovascular aortic repair (TEVAR) using a new adjustable needle puncturing device system. methods It is a multicentre, retrospective, physician-initiated cohort study of patients treated from 28 july 2021 to 3 april 2024. Inclusion criteria were isolate left subclavian artery revascularization for elective or urgent/emergent 'zone 2' TEVAR. the primary outcome was technical success and freedom from ISF TEVAR-related reintervention or endoleak. results we treated 50 patients: 28 (56.0%) atherosclerotic thoracic aneurysms, 12 (24.0%) type B aortic dissection and 10 (20.0%) penetrating aortic ulcers. elective intervention was carried out in 46 (92.0%) cases. ISF was successful in all cases, with a procedural primary technical success in 47 (94.0%) cases. the median time of intervention was 184 min (interquartile range 135-220) with a median fenestration time of 20 min (interquartile range 13-35). operative mortality did not occur. we observed 1 case of spinal cord ischaemia and 2 cases of bilateral posterior non-disabling stroke. mortality at 30 days occurred in 1 (2.0%) patient (not aorta-related). the median follow-up was 4 months (interquartile range 1-12.25). bridging stent graft patency was 100% with no ISF-related endoleak. ISF-related reintervention was never required conclusions ISF TEVAR using the ankura (TM)-II device with the self-centring adjustable needle system showed high technical success, promising stability and stable aortic-related outcomes. owing to these results, it represents a safe and effective alternative for standard 'zone 2' TEVAR.| File | Dimensione | Formato | |
|---|---|---|---|
|
2025 REGISTRO ANKURA.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
3.26 MB
Formato
Adobe PDF
|
3.26 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


