OBJECTIVES: Endovascular aortic arch stent grafting with branched devices has shown initial promising results. The aim of this prospective, multicentre study was to evaluate 3-year outcomes of aortic arch stent grafting with NEXUS, Aortic Arch Stent Graft System (Nexus), a single-branch, bi-modular, off-the-shelf aortic arch stent graft system in high-risk patients. METHODS: Patients treated with Nexus, either under the feasibility clinical study or as compassionate use procedures in 5 centres, were included in this study. The primary end point was overall survival. The secondary end points included the incidence of procedure-related unplanned intervention, stroke, paraplegia and endoleak. Clinical and radiologic follow-up was performed at each study site at 30days, 6months and onayearly basis thereafter up to 3years postoperatively. RESULTS: We analysed data from a total of 28 patients. The overall median follow-up was 1132 (interquartile range: 809–1537). There were no device or procedure-related deaths between 1 and 3 years. Overall survival at 1 and 3 years was 89% and 71%, respectively. The cumulative incidence of unplanned reintervention at 1 and 3 years was 11% and 29%, respectively. There were no reports of stroke, paraplegia, aneurysm rupture, myocardial infarction or new aortic valve insufficiency. In this study’s 1–3year follow-up period, 1 type Ib (4%), 1 type II (4%) and 2 type III (8%; between Nexus’ distal end and Thoracic endovascular aortic repair (TEVAR) extensions) endoleak were detected. CONCLUSIONS: Endovascular aortic arch exclusion with the single-branch, off-the-shelf Nexus system provides promising clinical and radiologic results at 3-year follow-up in a high-risk patient cohort.

D'Onofrio, A., Lachat, M., Mangialardi, N., Antonello, M., Schelzig, H., Chaykovska, L., et al. (2023). Three-year follow-up of aortic arch endovascular stent grafting with the Nexus device: results from a prospective multicentre study. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 63(1) [10.1093/ejcts/ezac561].

Three-year follow-up of aortic arch endovascular stent grafting with the Nexus device: results from a prospective multicentre study

Augusto D'Onofrio
Writing – Original Draft Preparation
;
2023-01-01

Abstract

OBJECTIVES: Endovascular aortic arch stent grafting with branched devices has shown initial promising results. The aim of this prospective, multicentre study was to evaluate 3-year outcomes of aortic arch stent grafting with NEXUS, Aortic Arch Stent Graft System (Nexus), a single-branch, bi-modular, off-the-shelf aortic arch stent graft system in high-risk patients. METHODS: Patients treated with Nexus, either under the feasibility clinical study or as compassionate use procedures in 5 centres, were included in this study. The primary end point was overall survival. The secondary end points included the incidence of procedure-related unplanned intervention, stroke, paraplegia and endoleak. Clinical and radiologic follow-up was performed at each study site at 30days, 6months and onayearly basis thereafter up to 3years postoperatively. RESULTS: We analysed data from a total of 28 patients. The overall median follow-up was 1132 (interquartile range: 809–1537). There were no device or procedure-related deaths between 1 and 3 years. Overall survival at 1 and 3 years was 89% and 71%, respectively. The cumulative incidence of unplanned reintervention at 1 and 3 years was 11% and 29%, respectively. There were no reports of stroke, paraplegia, aneurysm rupture, myocardial infarction or new aortic valve insufficiency. In this study’s 1–3year follow-up period, 1 type Ib (4%), 1 type II (4%) and 2 type III (8%; between Nexus’ distal end and Thoracic endovascular aortic repair (TEVAR) extensions) endoleak were detected. CONCLUSIONS: Endovascular aortic arch exclusion with the single-branch, off-the-shelf Nexus system provides promising clinical and radiologic results at 3-year follow-up in a high-risk patient cohort.
2023
Pubblicato
Rilevanza internazionale
Articolo
Comitato scientifico
Settore MED/23
Settore MEDS-13/C - Chirurgia cardiaca
English
Con Impact Factor ISI
D'Onofrio, A., Lachat, M., Mangialardi, N., Antonello, M., Schelzig, H., Chaykovska, L., et al. (2023). Three-year follow-up of aortic arch endovascular stent grafting with the Nexus device: results from a prospective multicentre study. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 63(1) [10.1093/ejcts/ezac561].
D'Onofrio, A; Lachat, M; Mangialardi, N; Antonello, M; Schelzig, H; Chaykovska, L; Hill, A; Holden, A; Lindsay, T; Ten Tan, K; Orrico, M; Ronchey, S; ...espandi
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
ezac561.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 589.77 kB
Formato Adobe PDF
589.77 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/397113
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 21
social impact